Truma 77400-01

Truma AquaGo Electric Antifreeze Kit User Manual

Eredua: 77400-01

Marka: Truma

1. Sarrera

This manual provides essential information for the safe and efficient operation of your Truma AquaGo Electric Antifreeze Kit. Please read this manual thoroughly before installation and use, and retain it for future reference.

The Truma AquaGo Electric Antifreeze Kit is designed to protect your Truma AquaGo Comfort or Truma AquaGo Comfort Plus water heater from freezing. It operates on 12V DC electricity, eliminating the need for LPG to prevent frost damage. This kit maintains the AquaGo system frost-free down to -4°F (-20°C), ensuring functionality even in cold conditions. It is intended solely for freeze protection and is not an alternative to propane for heating water for consumption. The kit works by heating the water inside the AquaGo and activating the circulation pump to move warm water throughout the system, preventing ice formation.

2. Segurtasun informazioa

OHARRA:

  • Deskonektatu beti korrontea edozein instalazio, mantentze-lan edo arazo-konponketa egin aurretik.
  • Instalazioa teknikari kualifikatu batek egin behar du funtzionamendu egokia eta segurtasuna bermatzeko.
  • Ensure all electrical connections are secure and properly insulated to prevent short circuits or electrical hazards.
  • This kit is for freeze protection only. It does not replace the primary heating function of the Truma AquaGo unit.
  • Do not operate the Truma AquaGo with the flue plug inserted when using propane for water heating. The flue plug is only for use when the antifreeze kit is active and the propane burner is off, especially during travel in freezing conditions.

3. Paketearen edukia

Instalazioarekin jarraitu aurretik, egiaztatu osagai guztiak daudela eta kalterik gabe daudela.

Truma AquaGo Electric Antifreeze Kit components including the main heating element, wiring harness, and yellow drain lever insert.

Figure 1: Contents of the Truma AquaGo Electric Antifreeze Kit. This image displays the main heating element, the yellow "easy drain lever" insert, and the associated wiring harness, along with the product packaging.

  • Electric Antifreeze Heating Element
  • "Easy Drain Lever" Insert (yellow component)
  • Kableatu Harness
  • Flue Plug (if included with specific model variant)
  • Muntatzeko hardwarea (aplikagarria bada)

4. Konfigurazioa eta instalazioa

The Truma AquaGo Electric Antifreeze Kit features a plug-and-play design for straightforward installation. However, professional installation is recommended.

4.1 Beharrezko tresnak

  • Basic hand tools (e.g., screwdriver, wire strippers/crimpers if modifying wiring)
  • Multimeter (for verifying power connections)

4.2 Instalazio-urratsak

  1. Prepare the AquaGo Unit: Ensure the Truma AquaGo unit is powered off and cooled down. Close any LPG supply valves.
  2. Locate the Easy Drain Lever: Identify the "easy drain lever" on your Truma AquaGo Comfort or Comfort Plus unit.
  3. Insert Antifreeze Kit: The electric antifreeze kit is designed to be inserted into the existing "easy drain lever" mechanism. Carefully align and insert the heating element and its housing.
  4. Konektatu kable-arnesa: Connect the provided wiring harness to the antifreeze kit and then to the designated connection point on your Truma AquaGo unit. Refer to your AquaGo unit's main manual for specific wiring diagrams if needed. The kit operates on 12V DC.
  5. Konexio seguruak: Ziurtatu konexio guztiak sendoak eta seguruak direla.
  6. Piztu eta probatu: Restore 12V DC power to the Truma AquaGo system. The system may require a reboot of the control panel to recognize the newly installed antifreeze kit. Monitor the system for proper operation.
Close-up of the Truma AquaGo Electric Antifreeze Kit heating element with mesh filter.

2. irudia: Xehetasuna view of the electric antifreeze heating element, showing the mesh filter and connection point. This component is inserted into the AquaGo's drain mechanism.

5. Funtzionamendu-argibideak

The Truma AquaGo Electric Antifreeze Kit is designed for automatic operation once installed and powered.

5.1 Activating Freeze Protection

  • Ensure the Truma AquaGo unit has 12V DC power supplied.
  • The kit will automatically activate when ambient temperatures approach freezing, circulating warm water within the AquaGo to prevent ice formation.
  • This system allows for freeze protection without the need to drain the water system or use LPG, even when the main burner is off or during travel.
  • If traveling in freezing conditions, it is recommended to insert the flue plug (if provided) into the AquaGo's exhaust flue to protect against wind chill, ensuring optimal performance of the antifreeze kit. Remember to remove the flue plug before operating the AquaGo with propane.

5.2 Kontuan hartu beharreko gauza garrantzitsuak

  • The antifreeze kit is a supplementary system for freeze protection, not a primary water heater.
  • Continuous 12V DC power is required for the kit to function.
  • The kit is effective down to approximately -4°F (-20°C). In extreme cold below this temperature, additional winterization measures may be necessary.

6. Mantentzea

The Truma AquaGo Electric Antifreeze Kit requires minimal maintenance.

  • Ohiko ikuskapena: Periodically inspect the heating element and wiring for any signs of wear, damage, or corrosion.
  • Garbiketa: If the heating element appears to have mineral deposits, it can be carefully removed and cleaned according to the Truma AquaGo main unit's descaling instructions. Ensure the unit is powered off and water drained before removal.
  • Biltegiratzea: If the RV or vehicle is stored for an extended period in freezing temperatures without power, it is still recommended to drain the entire water system, including the Truma AquaGo, to prevent damage.

7. Arazoak

If you encounter issues with your Truma AquaGo Electric Antifreeze Kit, refer to the following table:

ArazoaKausa posibleaIrtenbidea
Antifreeze kit not activating.No 12V DC power.
Control panel not recognizing kit.
Ambient temperature not low enough.
Check 12V DC power supply to the AquaGo unit.
Reboot the Truma control panel.
Verify ambient temperature is below activation threshold.
Water still freezing despite kit operation.Extreme cold beyond kit's capacity.
Insufficient water circulation.
Berogailu akastuna.
Consider additional winterization or draining the system in extreme conditions.
Ensure AquaGo pump is functioning correctly.
Contact Truma support for inspection/replacement.
Error message on Truma control panel.Connection issue or component failure.Refer to your Truma AquaGo main manual for specific error codes. Check wiring connections.

If problems persist, contact Truma customer support.

8. Zehaztapenak

EzaugarriXehetasuna
Modelo zenbakia77400-01
Elikatze Hornidura12V DC
Izozte babesteko tenperatura-4°F (-20°C) arte
BateragarritasunaTruma AquaGo Comfort, Truma AquaGo Comfort Plus
Elementuaren pisua15.8 ontza (gutxi gorabehera 0.45 kg)
Paketearen neurriak9.09 x 6.34 x 3.03 hazbete (gutxi gorabehera 23.1 x 16.1 x 7.7 cm)
FabrikatzaileaTruma

9. Bermearen informazioa

Truma products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Truma website. Typically, Truma offers a limited warranty against defects in materials and workmanship from the date of purchase.

Gorde erosketa-froga berme-erreklamazioetarako.

10. Bezeroarentzako arreta

For technical assistance, troubleshooting, or warranty inquiries, please contact Truma customer support:

  • Webgunea: www.truma.com
  • Telefonoa: Refer to the Truma webeskualdeko harremanetarako zenbakietarako gunea.
  • Posta elektronikoa: Refer to the Truma webharremanetarako helbide elektronikorako gunea.

Laguntzarekin harremanetan jartzean, eduki eskura zure produktuaren modelo zenbakia (77400-01) eta erosketaren frogagiria.

Erlazionatutako dokumentuak - 77400-01

Aurreview Truma AquaGo AU LP Gas Instant Water Heater: Operating Instructions
Comprehensive operating instructions and safety guidelines for the Truma AquaGo AU LP Gas Instant Water Heater, designed for recreational vehicles (RVs). Learn about installation, operation, maintenance, and troubleshooting.
Aurreview Truma AquaGo Water Heater Error Codes and Troubleshooting Guide
Comprehensive guide to Truma AquaGo water heater error codes, flash patterns, and troubleshooting steps. Learn how to identify and resolve common malfunctions.
Aurreview Truma CP plus Erabilera Argibideak
Truma CP plus kontrol-panelerako funtzionamendu-argibide osoak, Truma Combi eta Aventa etxetresna elektrikoen funtzioak, konfigurazioa eta arazoak konpontzea zehaztuz.
Aurreview Truma CP plus Panel de Control Digital: Manual de Operación y Instalación
Manual completo para el panel de control digital Truma CP plus, detallando su operación, instalación, seguridad y resolución de problemas para sistemas de calefacción Truma Combi en vehículos recreativos.
Aurreview Truma AquaGo Decalcification Instructions and Maintenance Guide
Detailed instructions for decalcifying your Truma AquaGo RV water heater. This guide covers procedures for both Analog Dial and CP plus controller models, including troubleshooting steps for common issues like being stuck in clean mode.
Aurreview Truma AquaGo LP Gas Instant Water Heater: Installation and Operating Manual
Comprehensive guide for the Truma AquaGo LP Gas Instant Water Heater, covering installation, operation, safety, maintenance, and troubleshooting for recreational vehicles (RVs).