York S1-3L01-230

York Control, Fan & Limit Snap Disc 230 Deg Instruction Manual

Marka: York | Eredua: S1-3L01-230

1. Produktua amaitu daview

The York Control, Fan & Limit Snap Disc 230 Deg is a crucial component designed for commercial HVAC units. This genuine OEM (Original Equipment Manufacturer) part ensures the safe and efficient operation of your equipment by providing precise temperature control and limit functions. It is engineered to meet original part specifications, guaranteeing exact fitment and reliable performance as a direct replacement.

York Control, Fan & Limit Snap Disc 230 Deg

Figure 1: York Control, Fan & Limit Snap Disc 230 Deg. This image displays the snap disc component, featuring its metal mounting plate, electrical terminals, and the yellow label indicating model and temperature specifications.

2. Ezaugarri nagusiak

  • Jatorrizko OEM pieza: Ensures authenticity and compatibility with York HVAC systems.
  • Segurtasuna eta fidagarritasuna: Designed to maintain high safety standards and consistent performance.
  • Egokitze zehatza: Engineered to match original specifications for seamless replacement.
  • Tenperatura kontrola: Functions as a fan and limit control, activating or deactivating based on temperature thresholds, specifically 230 degrees.

3. Zer dago kutxan

Upon opening the packaging, you will find the following component:

  • One (1) York Control, Fan & Limit Snap Disc 230 Deg (Model: S1-3L01-230)

4. Zehaztapen Teknikoak

AtributuaXehetasuna
Produktuaren neurriak2 x 2 x 2 hazbete
Elementuaren pisua0.63 ontza
Modelo zenbakiaS1-3L01-230
FabrikatzaileaYork
Tenperaturaren balorazioa230 Degrees Fahrenheit (as indicated by "230 Deg" in product title)
Zati motaControl, Fan & Limit Snap Disc

5. Konfigurazioa eta instalazioa

Segurtasun informazio garrantzitsua: Installation of this component should only be performed by a qualified HVAC technician. Ensure that the power supply to the HVAC unit is completely disconnected before beginning any installation or maintenance work. Failure to do so can result in serious injury or damage to the equipment.

  1. Potentzia deskonexioa: Locate the main power switch for your HVAC system and turn it OFF. Verify that no power is reaching the unit using a voltage probatzailea.
  2. Osagaira sartu: Open the access panel of your HVAC unit to locate the existing fan and limit control snap disc.
  3. Deskonektatu kableatuak: Carefully note the wiring connections to the old snap disc. It is recommended to take a photograph or draw a diagram of the connections before disconnecting. Disconnect all wires from the old component.
  4. Kendu osagai zaharra: Unscrew or unclip the old snap disc from its mounting bracket.
  5. Osagai berria instalatu: Position the new York Control, Fan & Limit Snap Disc (Model S1-3L01-230) into the mounting bracket. Secure it firmly using the appropriate screws or clips.
  6. Kableatua berriro konektatu: Reconnect the wires to the new snap disc according to the diagram or photograph taken earlier. Ensure all connections are secure and properly insulated.
  7. Sarbide Seguruaren Panela: Close and secure the HVAC unit's access panel.
  8. Berrezarri boterea: Turn the main power switch for your HVAC system back ON.
  9. Proba funtzionamendua: Monitor the HVAC unit's operation to ensure the new snap disc is functioning correctly, activating the fan and limit controls as expected based on temperature.

6. Funtzionamendua

The York Control, Fan & Limit Snap Disc is an automatic thermal switch designed to respond to temperature changes within the HVAC system. Its primary functions are:

  • Fan kontrola: The snap disc monitors the temperature in the furnace plenum or heat exchanger. When the temperature rises to a predetermined set point (e.g., for fan activation), the bimetallic disc "snaps" to close a circuit, turning on the furnace fan to distribute heated air.
  • Mugen kontrola: If the temperature continues to rise beyond a safe operating limit (e.g., 230 degrees Fahrenheit), the snap disc will "snap" to open a circuit, shutting down the burner to prevent overheating and potential damage to the furnace. This acts as a critical safety mechanism.

The snap disc operates automatically and does not require manual intervention during normal system operation. Its design ensures reliable and precise temperature-based switching.

7. Mantentzea

The York Control, Fan & Limit Snap Disc is a sealed component and generally requires no routine maintenance. However, periodic inspection of the component and its connections is recommended as part of a comprehensive HVAC system maintenance schedule.

  • Ikus-ikuskapena: During routine HVAC system checks, visually inspect the snap disc for any signs of physical damage, corrosion, or loose wiring connections.
  • Garbitasuna: Ensure the area around the snap disc is free from dust, debris, or obstructions that could affect its temperature sensing capabilities.
  • Egiaztapen profesionala: It is advisable to have a qualified HVAC technician inspect the snap disc's functionality and calibration during annual system servicing.

If any issues are observed, or if the HVAC system exhibits unusual fan or heating behavior, consult a qualified technician for diagnosis and potential replacement.

8. Arazoak

This section provides guidance on common issues related to the fan and limit control. For complex problems, always consult a qualified HVAC technician.

ArazoaKausa posibleaIrtenbidea
Furnace fan not turning onFaulty snap disc (fan control), clogged air filter, thermostat issue, motor problem.Check air filter. Verify thermostat settings. If other components are fine, the snap disc may need replacement. Consult a technician.
Furnace overheating / frequently shutting offFaulty snap disc (limit control), restricted airflow, dirty burners, oversized furnace.Ensure all vents are open. Check for obstructions in ductwork. Clean burners if accessible. If problem persists, the limit control may be faulty. Professional diagnosis is required.
Haizagailuak etengabe funtzionatzen duSnap disc contacts stuck closed, thermostat fan setting on "ON", short circuit in wiring.Check thermostat fan setting and set to "AUTO". If fan still runs, the snap disc may be faulty and require replacement. Inspect wiring for shorts.

Oharra: Always disconnect power to the HVAC unit before attempting any inspection or repair.

9. Bermea eta Laguntza

As a genuine OEM part, the York Control, Fan & Limit Snap Disc (Model S1-3L01-230) is typically covered by the manufacturer's standard warranty for replacement parts. Specific warranty terms and duration may vary. Please retain your proof of purchase for warranty claims.

Bezeroarentzako laguntza:

For technical assistance, warranty inquiries, or to locate authorized service providers, please contact York customer support or visit their official website. Always refer to the official York documentation for the most accurate and up-to-date support information.

York Official Webgunea: www.york.com (Oharra: Hau leku-markatzailea da URL. Please refer to official product documentation for the correct support contact information.)

Erlazionatutako dokumentuak - S1-3L01-230

Aurreview York Affinity Series Central Dehumidifiers: Whole-Home Humidity Control & Air Quality
Discover the York Affinity Series Central Dehumidifiers, designed to enhance your home's indoor air quality by effectively managing humidity. Learn how these units provide whole-home comfort, protect against mold and allergens, prevent structural damage, and offer energy savings. Features include easy maintenance and a 5-year warranty. Explore sizing guidelines and installation options.
Aurreview YORK-Y409 Bainuontzi independentea: Instalazio, mantentze eta segurtasun gida
YORK-Y409 bainuontzi independentearen gida osoa, produktuaren ezaugarriak, instalazio-argibide zehatzak (zoru azpiko sarbidearekin eta gabe), mantentze-aholkuak, garbiketa-prozedurak, marradurak kentzea eta segurtasun-abisu garrantzitsuak biltzen dituena. Produktuaren neurriak eta bermearen informazioa barne hartzen ditu.
Aurreview YORK Chiller Materials Application and Chemicals Limit Guide for Various Water Qualities
A comprehensive guide from Johnson Controls detailing material application and chemical limits for YORK chillers across various water qualities, including potable, non-potable, treated sewage effluent (TSE), seawater, and brackish water. It provides essential safety guidelines and component recommendations for optimal chiller performance and longevity.
Aurreview YORK Champion Series D1NA/D2NA Single Package Gas/Electric Air Conditioner Installation Instructions
Comprehensive installation guide for YORK Champion Series D1NA and D2NA single package gas/electric air conditioners. Covers general information, inspection, parts, safety warnings, installation procedures, wiring, gas piping, maintenance, and troubleshooting for models D1NA018 through D1NA048 and D2NA060.
Aurreview York PS9 Serieko % 90eko beheranzko/horizontaleko gas naturaleko labeen piezen zerrenda
York PS9 Serieko % 90eko beheranzko/horizontaleko gas naturaleko labeen piezen zerrenda osoa eta diagramak, PS9B12N060DH11A, PS9B12N080DH11A, PS9C16N080DH11A, PS9C16N100DH11A, PS9C20N100DH11A eta PS9D20N120DH11A modelo zenbakiak barne. Osagaien identifikazioa eta piezen zenbakiak ditu.
Aurreview York DGAA eta DGAH Eraginkortasun Handiko Gas Labea: Erabiltzaile, Mantentze eta Zerbitzu Eskuliburua
York DGAA eta DGAH eraginkortasun handiko errekuntza-gas zigilatutako labeen gida osoa, segurtasuna, instalazioa, funtzionamendua, mantentze-lanak, arazoak konpontzea eta piezak biltzen dituena.