Thank you for choosing the Rebel POWER-1000 Pure Sine Wave UPS Inverter. This device is designed to provide stable and safe emergency power for various applications, including central heating furnaces, heat pumps, refrigerators, and other RTV/AGD systems. It features a pure sine wave output, ensuring compatibility with sensitive electronic and inductive loads, and offers three operating modes: emergency power supply (UPS), rectifier (charger), and inverter.

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your POWER-1000 inverter. Please read it thoroughly before use and retain it for future reference.

2. Segurtasun-argibideak

Beti jarraitu segurtasun neurri hauek gailuari lesioak edo kalteak saihesteko:

3. Produktuaren osagaiak

Familiarize yourself with the main components of your Rebel POWER-1000 UPS Inverter:

Aurrealdea view of Rebel POWER-1000 UPS Inverter showing the LED display and main power switch.

3.1. irudia: Aurrealdeko panela
This image displays the front of the Rebel POWER-1000 inverter, featuring the LED display which shows operational status, battery charge, and load level. Below the display is the main ON/OFF switch.

Atzekoa view of Rebel POWER-1000 UPS Inverter with battery cables, AC input, and output sockets.

3.2 irudia: Atzeko panela goianview
This image shows the rear panel of the inverter. Visible components include the cooling fan, circuit breaker, two output sockets, battery connection terminals (red and black cables), and the AC input socket.

Close-up of the rear panel connections on Rebel POWER-1000 UPS Inverter.

Figure 3.3: Rear Panel Connections Detail
Hurbilago bat view of the rear panel, highlighting the 'OUTPUT' sockets for connecting appliances, the 'BATTERY +12V' terminals for external battery connection, the 'AC INPUT 230V' for mains power, and the 'CIRCUIT BREAKER' for protection.

Funtsezko osagaiak:

4. Konfigurazioa

Follow these steps to set up your Rebel POWER-1000 UPS Inverter:

  1. Despaketatzea: Carefully remove the inverter from its packaging. Inspect for any signs of damage.
  2. Lekua: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient space around the unit for airflow.
  3. Bateria konexioa:
    • Ziurtatu inbertsorearen korrontea itzalita dagoela.
    • Konektatu gorria bateriaren kablea -ra positiboa (+) terminal of your 12V DC battery.
    • Konektatu beltza bateriaren kablea -ra negatiboa (-) terminal of your 12V DC battery.
    • Tighten all connections securely to prevent arcing.
  4. AC sareko konexioa: Plug the inverter's AC input cable into a standard 230V AC wall outlet.
  5. Gailuaren konexioa: Plug the devices you wish to power into the 230V AC output sockets on the rear of the inverter. Ensure the total power consumption of connected devices does not exceed 700 W.

5. Funtzionamendu-argibideak

The Rebel POWER-1000 operates in three main modes:

Starting the Inverter:

  1. Ensure all connections (battery, AC input, loads) are secure.
  2. Press the main ON/OFF switch on the front panel. The LED display will illuminate, indicating the current operating status, battery charge, and load level.
  3. The inverter will automatically select the appropriate operating mode based on the presence of mains power and connected loads.

LED Display Information:

The clear LED display provides crucial information:

6. Mantentzea

Mantentze-lan erregularrak zure inbertsorearen errendimendu optimoa eta iraupena bermatzen ditu:

7. Arazoak

If you encounter issues with your Rebel POWER-1000, refer to the following table:

ArazoaKausa posibleaIrtenbidea
Inbertsoreak ez du piztenNo battery connected or battery discharged; Main switch off; Blown circuit breaker.Connect a charged battery; Turn on the main switch; Check and reset the circuit breaker on the rear panel.
AC irteerarik ezOverload; Short circuit; Battery low; Inverter fault.Reduce connected load; Check for short circuits in connected devices; Recharge or replace battery; If problem persists, contact support.
Bateria ez da kargatzenAC input not connected; AC input voltage too low/high; Battery fault.Ensure AC input cable is securely plugged in; Check mains voltage; Test battery or replace if faulty.
Overload warning on displayTotal power of connected devices exceeds 700 W.Disconnect some devices to reduce the load below 700 W.
Unit is unusually hotBlocked ventilation; Excessive load; High ambient temperature.Ensure vents are clear; Reduce load; Move unit to a cooler environment.

If the problem persists after attempting these solutions, please contact Rebel customer support or your retailer.

8. Zehaztapenak

Technical specifications for the Rebel POWER-1000 UPS Inverter (Model RB-4003):

EzaugarriZehaztapena
Potentzia nominala700 W (1000 VA)
Bateria mota12 V DC
Gehienezko bateria boltage15 V DC
Sarrera boltage Barrutia190 - 260 V korronte alternoa
Sarrerako maiztasuna45 - 60 Hz
Irteera boltage (AC)230 V AC +/-5% (Inverter: 230 V AC +/-3%)
Irteerako maiztasuna50/60 Hz +/-0.5 Hz
Irteerako uhin formaSine Wave Pure
Irteeraren eraginkortasuna>= 85% (DC to AC)
Bateria kargatzeko korronteaGehienez 10 A
Iradokitako bateriaren edukiera50-200 Ah (suggested: 55 Ah)
Kargatutako denbora kalkulatua4-14 hours (dependent on battery capacity)
Aldaketa Ordua=<4 ms
BabesakOverload, Short Circuit, Over/Under Voltage
Funtzionamendu-tenperatura0 - 40 °C
Funtzionamenduaren hezetasuna% 10 - % 90
Neurriak (L x W x H)336 x 143 x 178 mm
Pisua4.3 kg

9. Bermea eta Laguntza

The Rebel POWER-1000 UPS Inverter is manufactured by Rebel. For warranty information, please refer to the warranty card included with your product or consult the retailer from whom you purchased the device. Keep your proof of purchase for warranty claims.

For technical support or service inquiries, please contact your local Rebel distributor or the point of purchase. Ensure you have your product model (RB-4003) and serial number (if applicable) ready when contacting support.

Erlazionatutako dokumentuak - RB-4003

Aurreview Erabiltzeko Rebel RB-4026, RB-4027, RB-4028 eskuliburua - Invertor de Putere
Ghid complet pentru utilizarea, instalarea și întreținerea invertorului de putere Rebel cu undă sinusoidală pură și încărcarearen funtzioa. Sartu segurtasun-instrukzioak, selekzio bateriei eta zehaztapen teknikoak.
Aurreview Rebel UPS etenik gabeko elikatze-iturriaren erabiltzailearen eskuliburua RB-4020-5
Rebel RB-4020, RB-4021, RB-4022, RB-4023, RB-4024, RB-4025 modeloen erabiltzailearen eskuliburua. Segurtasun-abisuak, sarrera, zehaztapenak, arazoak konpontzea eta behar bezala botatzeko informazioa barne hartzen ditu.
Aurreview Rebel MIE-RB-33B, C, D multimetro digitalaren erabiltzailearen eskuliburua
Rebel MIE-RB-33B, MIE-RB-33C eta MIE-RB-33D modeloen erabiltzailearen eskuliburua. Segurtasun-argibideak, produktuaren deskribapena, funtzionamendu-gida, zehaztapenak eta mantentze-informazioa barne hartzen ditu.
Aurreview Rebel RB-1003 Haririk gabeko bihurkinaren erabiltzailearen eskuliburua
Get detailed instructions and safety information for the Rebel RB-1003 Cordless Screwdriver. This user manual covers operation, maintenance, and troubleshooting for your Rebel tools.
Aurreview Rebel Power Inverter Erabiltzailearen Eskuliburua
Rebel Power Inverterren erabiltzailearen eskuliburu osoa, URZ3160-62, URZ3164-65, URZ3167-68 modeloen instalazioa, funtzionamendua, segurtasuna, arazoak konpontzea eta zehaztapenak biltzen dituena.
Aurreview Rebel MIE-RB-55 Multimetro Digitalaren Erabiltzaile Eskuliburua
Rebel MIE-RB-55 multimetro digitalaren erabiltzailearen eskuliburu osoa, segurtasun-argibideak, produktuaren deskribapena, funtzionamendua, mantentze-lanak eta zehaztapen teknikoak biltzen dituena.