1. Sarrera

The GIMA Mission Cholesterol Meter 23932 is a portable device designed for the quantitative measurement of various lipid parameters in whole blood, serum, or plasma. This manual provides essential information for the safe and effective operation of your device, including setup, testing procedures, maintenance, and troubleshooting.

The meter reliably measures Total Cholesterol (CHOL), High-Density Lipoprotein (HDL) Cholesterol, and Triglycerides (TRIG). It also calculates Low-Density Lipoprotein (LDL) Cholesterol and the CHOL/HDL ratio, providing a comprehensive lipid panel for health monitoring.

Two GIMA Mission Cholesterol Meters in their packaging, showing the device, test strips, and manual.

1.1. irudia: GIMA Mission Cholesterol Meter 23932 (Two-Pack). This image displays two complete kits, each containing the meter, test strips, and user manual, as they appear in their retail packaging.

2. Segurtasun informazio garrantzitsua

Please read all instructions carefully before using the GIMA Mission Cholesterol Meter. Failure to follow instructions may result in inaccurate readings or device malfunction.

  • Gailu hauentzat pentsatuta dago in vitro erabilera diagnostikoa soilik.
  • Do not use the meter for purposes other than lipid panel testing.
  • Always use fresh, unexpired test strips specifically designed for the GIMA Mission Cholesterol Meter.
  • Handle blood samples with care, following universal precautions for biohazardous materials.
  • Keep the device and test strips out of reach of children.
  • Consult a healthcare professional for interpretation of test results and medical advice.

3. Paketearen edukia

Upon opening the package, verify that all components are present and undamaged. The standard package for the GIMA Mission Cholesterol Meter 23932 typically includes:

  • GIMA Mission Cholesterol Meter
  • Erabiltzailearen eskuliburua
  • Batteries (often included)
  • Eramateko zorroa (paketearen arabera alda daiteke)
  • Note: Test strips and control solutions are sold separately.

4. Gailuaren konfigurazioa

4.1. Pilak sartzea

  1. Bilatu bateriaren konpartimentuaren estalkia neurgailuaren atzealdean.
  2. Lerratu estalkia ireki.
  3. Insert the specified batteries (e.g., AAA batteries) according to the polarity indicators (+/-).
  4. Itxi bateriaren konpartimenduaren estalkia ondo.

4.2. Hasierako ezarpenak

Upon first power-on or after battery replacement, you may need to set the date and time. Refer to the on-screen prompts and use the navigation buttons to adjust these settings.

Close-up of the GIMA Mission Cholesterol Meter's display showing a reading of 228 mg/dL for CHOL, along with date and time.

4.1. irudia: GIMA Mission Cholesterol Meter Display. This image shows the meter's LCD screen, indicating a cholesterol reading, date, and time, along with navigation buttons.

5. Operating Instructions: Performing a Test

Before starting, ensure you have the GIMA Mission Cholesterol Meter, appropriate test strips (e.g., Total Cholesterol, HDL, Triglycerides), a lancing device, and lancets. Ensure your hands are clean and dry.

A Mission Cholesterol control solution bottle and a single test strip.

5.1. irudia: Test Strip and Control Solution. This image shows a bottle of Mission Cholesterol control solution and a single test strip, essential components for accurate testing.

  1. Prepare the Meter: Piztu neurgailua pizteko botoia sakatuz.
  2. Txertatu proba-banda: Carefully insert a new test strip into the meter's test strip port. The meter will typically display a code or a symbol indicating it's ready for a blood sample.
  3. Lortu odola Sample: Use a lancing device to obtain a small drop of blood from your fingertip.
  4. Aplikatu Blood Sample: Ukitu proba-bandaren punta odolariample. The strip will draw the blood into the reaction area. Ensure the sample completely fills the designated area on the strip.
  5. Irakurri emaitzak: The meter will begin a countdown. After the specified time (typically 2 minutes), the results will be displayed on the screen.
Three-step diagram showing how to use the GIMA Mission Cholesterol Meter: 1. Insert device into meter, 2. Apply specimen with capillary transfer tube, 3. Read result.

5.2. irudia: Step-by-Step Testing Process. This diagram illustrates the three key steps for performing a test: inserting the test strip, applying the blood sample using a capillary tube, and reading the final result on the meter's display.

5.1. Key Features for Reliability and Ease of Use

GIMA Mission Cholesterol Meter display with text highlighting features: Maximum Reliability, Can test whole blood, serum or plasma, Wide hematocrit range 0-50%, Small printer available, Easy to use, Large LCD screen for easy reading, Batteries included.

5.3. irudia: Meter Features. This image highlights the key features of the GIMA Mission Cholesterol Meter, emphasizing its reliability, versatility in sample types, wide hematocrit range, optional printer, ease of use, clear LCD screen, and included batteries.

  • Versatile Sample Motak: Can test whole blood, serum, or plasma.
  • Wide Hematocrit Range: Supports a hematocrit range of 0-50%, ensuring accuracy across various blood conditions.
  • Optional Printer: A small printer is available for immediate result printouts (sold separately).
  • Erabiltzaileentzako diseinua: Designed for ease of use.
  • Garbitu pantaila: Features a large LCD screen for easy reading of results.
  • Bateriak barne: Ready for use upon purchase.
A GIMA Mission Cholesterol Meter in the foreground with a smiling couple in the background, emphasizing 'EASY TO USE'.

5.4. irudia: Ease of Use. This image visually reinforces the user-friendly nature of the GIMA Mission Cholesterol Meter, showing it in a relatable context.

6. Understanding Your Results

The GIMA Mission Cholesterol Meter provides readings for several lipid parameters:

  • CHOL (Total Cholesterol): The total amount of cholesterol in your blood.
  • HDL (High-Density Lipoprotein): Often called "good" cholesterol, it helps remove excess cholesterol from the body.
  • TRIG (Triglycerides): A type of fat found in your blood. High levels can increase the risk of heart disease.
  • LDL (Low-Density Lipoprotein): Often called "bad" cholesterol, high levels can lead to plaque buildup in arteries. This value is calculated by the meter.
  • CHOL/HDL Ratio: A calculated ratio that can provide additional insight into cardiovascular risk.

Garrantzitsua: Reference ranges for lipid levels can vary based on age, gender, and individual health conditions. Always discuss your results with a healthcare professional for proper interpretation and guidance.

7. Zainketa eta Mantentzea

7.1. Cleaning the Meter

  • Wipe the exterior of the meter with a soft, damp oihal.
  • Do not use abrasive cleaners or immerse the meter in water.
  • Ensure no liquid enters the test strip port or battery compartment.

7.2. Biltegiratzea

  • Store the meter and test strips in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Keep test strips in their original sealed container until ready for use.
  • Neurgailua denbora luzez erabiliko ez bada, kendu bateriak isuriak saihesteko.

8. Arazoak

If you encounter issues with your GIMA Mission Cholesterol Meter, refer to the following common problems and solutions:

ArazoaKausa posibleaIrtenbidea
Neurgailua ez da pizten.Pila hilak edo gaizki sartutakoak.Ordeztu bateriak edo ziurtatu polaritate zuzenarekin sartuta daudela.
Errore-mezua pantailan.Expired test strip, insufficient blood sample, or strip inserted incorrectly.Check test strip expiration date, re-test with a new strip and sufficient sample, ensure strip is fully inserted.
Irakurketa okerrak.Improper storage of strips, contamination, or incorrect testing procedure.Review storage conditions, ensure clean hands and meter, follow testing steps precisely. Perform a control solution test if available.

If the problem persists, contact GIMA customer support for assistance.

9. Zehaztapenak

  • Modelo zenbakia: 23932
  • Neurriak: 14 x 8 x 25 cm
  • Pisua: 600 gramo
  • Neurketa-parametroak: Total Cholesterol (CHOL), HDL Cholesterol, Triglycerides (TRIG), calculated LDL Cholesterol, CHOL/HDL ratio.
  • Sample Mota: Whole blood, serum, or plasma
  • Hematokritoaren barrutia: % 0-50
  • Proba ordua: 2 minutu inguru
  • Energia iturria: Batteries (type typically specified on device or packaging)
  • Fabrikatzailea: ACON BIOTECH (HANGZHOU) CO. LTD.

10. Bermea eta bezeroarentzako laguntza

For warranty information, please refer to the documentation included with your purchase or visit the official GIMA website. For technical support, questions regarding device operation, or to order replacement parts and test strips, please contact GIMA customer service.

GIMA Contact Information: (Please refer to your product packaging or GIMA's official webwebgunea kontaktu-datu eguneratuenak lortzeko.)