Generac RXSW200A3 & 7101

Generac 200 Amp Automatic Smart Transfer Switch Kit & Battery Heater Pad User Manual

Model: RXSW200A3 & 7101

1. Sarrera eta Produktuaren Azalpenaview

This manual provides essential information for the safe and efficient operation of your Generac 200 Amp Single Phase Automatic Smart Transfer Switch Kit and the Generac 7101 Battery Heater Pad. This combined system is designed to ensure continuous power supply during utility outages and maintain optimal battery performance for your standby generator.

The Generac Automatic Transfer Switch is engineered for use with single-phase generators equipped with an Evolution or Nexus Controller. It monitors utility power and automatically transfers the electrical load between utility and generator power, ensuring seamless operation. Its Digital Power Management (DPM) technology allows for the management of up to four individual HVAC (24 VAC controlled) loads without additional hardware.

The Generac 7101 Battery Heater Pad is designed to maintain the optimal temperature of your generator's battery, especially in colder climates. It activates automatically to prevent performance degradation due to low temperatures.

Generac 200 Amp Automatic Smart Transfer Switch Kit and Battery Heater Pad

1 Irudia: Gainetikview of the Generac 200 Amp Automatic Smart Transfer Switch Kit and 7101 Battery Heater Pad, showing the transfer switch enclosure, battery heater pad, and associated wiring/ties.

2. Segurtasun informazioa

OHARRA: Installation and service must be performed by a qualified electrician or service technician. Improper installation or maintenance can result in serious injury, death, or property damage.

  • Always disconnect all power sources before servicing the transfer switch or battery heater pad.
  • Ensure all local electrical codes and regulations are followed during installation.
  • Erabili babes pertsonaleko ekipamendu (BPE) egokia, segurtasun-betaurrekoak eta eskularru isolatzaileak barne.
  • Do not operate the transfer switch or heater pad if any components are damaged.
  • Keep children and unauthorized personnel away from the equipment.

3. Produktuaren osagaiak

The Generac 200 Amp Automatic Smart Transfer Switch Kit and 7101 Battery Heater Pad include the following main components:

  • Generac 200 Amp Automatic Smart Transfer Switch: Housed in an aluminum NEMA/UL type 3R enclosure.
  • Generac 7101 Battery Heater Pad: Designed for 9kW-22kW air-cooled standby generators.
  • Associated wiring and installation accessories (e.g., cable ties).
Exterior of Generac 200 Amp Automatic Smart Transfer Switch

2 irudia: Kanpoaldea view of the Generac 200 Amp Automatic Smart Transfer Switch enclosure.

Interior of Generac 200 Amp Automatic Smart Transfer Switch

3. Irudia: Barrualdea view of the Generac 200 Amp Automatic Smart Transfer Switch, showing internal components and wiring terminals.

Generac 7101 Battery Heater Pad with wiring

Figure 4: The Generac 7101 Battery Heater Pad, including its power cable and connection points.

4. Konfigurazioa eta instalazioa

Proper installation is crucial for the safe and effective operation of your transfer switch and battery heater pad. It is highly recommended that installation be performed by a certified electrician or Generac authorized service dealer.

4.1. Automatic Transfer Switch Installation

  1. Gunearen hautaketa: Choose a location for the transfer switch that is accessible, protected from severe weather, and in close proximity to both the utility meter and the generator. The NEMA 3R enclosure is suitable for outdoor use.
  2. Muntaketa: Securely mount the transfer switch enclosure to a sturdy surface using appropriate hardware. Ensure it is level and plumb.
  3. Kableatu konexioak:
    • Utility Power: Connect the utility power lines to the designated terminals within the transfer switch. This unit includes a service disconnect.
    • Generator Power: Connect the generator power lines to the appropriate terminals.
    • Karga konexioak: Connect the household electrical load to the transfer switch output terminals.
    • Kontrol-kableatzea: Konektatu bolumen baxuatage control wires between the transfer switch and the generator's Evolution or Nexus Controller. Refer to your generator's manual for specific control wiring diagrams.
  4. Lotura eta lotura: Ensure proper grounding and neutral bonding as per local electrical codes.
  5. Azken egiaztapenak: Before restoring power, double-check all connections for tightness and correct polarity.
Barnealde angeluatua view of Generac 200 Amp Automatic Smart Transfer Switch

Figure 5: Angled interior view of the transfer switch, highlighting the utility source connections (N1, N2), generator source, and customer load connections.

4.2. Battery Heater Pad Installation

The Generac 7101 Battery Heater Pad is designed for easy installation under the generator battery. It is compatible with air-cooled standby generators manufactured in 2008 or later. Note: This heater pad is not required for use with AGM-style batteries.

  1. Bateria kentzea: Carefully disconnect and remove the generator battery from its tray.
  2. Alfonbra kokapena: Place the Generac 7101 Battery Heater Pad directly onto the battery tray, ensuring it is centered and flat.
  3. Battery Reinstallation: Carefully place the battery back onto the heater pad in the tray. Reconnect the battery terminals, ensuring correct polarity.
  4. Kableatu konexioa: Connect the heater pad's wiring to the designated low-voltage power source on your generator, as specified in your generator's installation manual.
  5. Kableatu segurua: Use the provided cable ties to secure the heater pad wiring, preventing it from interfering with moving parts or being damaged.
Close-up of Generac 7101 Battery Heater Pad connector

6. irudia: hurbileko planoa view of the connector for the Generac 7101 Battery Heater Pad.

Close-up of Generac 7101 Battery Heater Pad wiring

7. irudia: Xehetasuna view of the wiring for the Generac 7101 Battery Heater Pad.

5. Funtzionamendu-argibideak

5.1. Automatic Transfer Switch Operation

The Generac Automatic Transfer Switch operates autonomously to manage your home's power supply.

  1. Utility Power Monitoring: The transfer switch continuously monitors the incoming utility power for interruptions or significant voltaggorabeherak.
  2. Automatic Transfer to Generator: Upon detecting a utility power outage, the transfer switch signals the standby generator to start. Once the generator reaches proper operating voltage and frequency, the transfer switch automatically disconnects the home from utility power and connects it to the generator power. This process is seamless and typically occurs within seconds.
  3. Digital Power Management (DPM): The integrated DPM allows the transfer switch to manage up to four 24 VAC controlled HVAC loads. During generator operation, if the total load approaches the generator's capacity, the DPM will shed non-essential HVAC loads to prevent overload, then reconnect them as capacity becomes available.
  4. Return to Utility Power: When stable utility power is restored, the transfer switch monitors it for a pre-set period to ensure stability. Once confirmed, it automatically transfers the electrical load back to utility power and signals the generator to cool down and shut off.

5.2. Battery Heater Pad Operation

The Generac 7101 Battery Heater Pad operates automatically based on ambient temperature to ensure your generator's battery remains at an optimal temperature for starting.

  • Aktibazio automatikoa: The heater pad is equipped with a thermostat that activates the heating element when the ambient temperature drops to approximately 40°F (4.4°C).
  • Desaktibazio automatikoa: The heater pad will turn off when the battery temperature reaches approximately 55°F (12.8°C), preventing overheating and conserving energy.
  • Etengabeko jarraipena: The heater pad continuously monitors the temperature, cycling on and off as needed to maintain the battery within the optimal temperature range.

6. Mantentzea

Regular maintenance ensures the longevity and reliable operation of your Generac transfer switch and battery heater pad. It is recommended to have these components inspected annually by a qualified technician as part of your generator's maintenance schedule.

  • Ikus-ikuskapena: Periodically inspect the transfer switch enclosure for any signs of damage, corrosion, or loose connections. Ensure the enclosure is sealed and free from debris.
  • Kableatuen egiaztapena: Verify that all wiring connections are secure and free from fraying or damage.
  • Garbitasuna: Keep the exterior of the transfer switch and the area around the battery heater pad clean and free of obstructions.
  • Bateria osasuna: Regularly check your generator's battery health. While the heater pad helps with temperature, the battery itself still requires proper charging and occasional testing.
  • Zerbitzu profesionala: For internal components of the transfer switch or any electrical issues, contact a Generac authorized service dealer. Do not attempt to service internal electrical components yourself.

7. Arazoak

This section provides basic troubleshooting steps for common issues. For complex problems, always contact a qualified Generac service technician.

ArazoaKausa posibleaIrtenbidea
Transfer switch does not transfer to generator during outage.
  • Generator not starting.
  • Control wiring issue.
  • Transfer switch malfunction.
  • Check generator fuel, oil, and battery.
  • Verify control wiring connections between switch and generator.
  • Jarri harremanetan teknikari kualifikatu batekin diagnostikoa egiteko.
Transfer switch does not return to utility power.
  • Utility power not stable.
  • Transfer switch malfunction.
  • Wait for utility power to stabilize.
  • Jarri harremanetan teknikari kualifikatu batekin.
Battery heater pad not warming battery.
  • Temperature above activation threshold.
  • Kableatu konexio soltea.
  • Heater pad malfunction.
  • Check ambient temperature (should be below 40°F/4.4°C).
  • Inspect wiring connections to the heater pad.
  • Jarri harremanetan teknikari kualifikatu batekin.

Garrantzitsua: Ez saiatu konponketa elektrikorik egiten gaituta ez bazaude. Eman beti lehentasuna segurtasunari.

8. Zehaztapenak

EzaugarriZehaztapena
Eragiketa moduaAutomatikoa
Egungo balorazioa200 Amps
Bolumen eragileatage240 Volt
Kontaktu motaNormalean irekita
Konektore mota2 Pin
TerminalaTorlojua
Zirkuitu Motanorabide bakarrekoa
Eragile motaBisagra Palanka
Harremanetarako materialaAltzairua
Nazioarteko Babesteko BalorazioaIP67
Postu kopurua1
Zehaztapena MetUL
Lower Temperature Rating (Heater Pad Activation)40 Fahrenheit gradu (4.4 °C)
Upper Temperature Rating (Heater Pad Deactivation)55 Fahrenheit gradu (12.8 °C)
Kontrol-metodoaTouch (for DPM interface, if applicable)
Konektibitate-protokoloaX-10 (for DPM, if applicable)
KoloreaOrange (Heater Pad)
Wattage6000 Watts (General product specification)
Unitate kopurua1.0 zenbaketa
Elementu kopurua1
FabrikatzaileaGenerac
MaterialaSteel (Transfer Switch Enclosure)

Oharra: Zehaztapenak alda daitezke abisurik gabe. Informazio zehatzena lortzeko, kontsultatu produktuaren etiketa.

9. Bermea eta Laguntza

Bermea: The Generac 200 Amp Automatic Smart Transfer Switch comes with a 5 urteko berme mugatua. The Generac 7101 Battery Heater Pad is also covered by Generac's standard accessory warranty. Please retain your proof of purchase for warranty claims.

Laguntza: For technical assistance, troubleshooting beyond this manual, warranty service, or to locate an authorized Generac service dealer, please visit the official Generac website or contact Generac customer support.

Visit the Official Generac Store on Amazon

Erlazionatutako dokumentuak - RXSW200A3 & 7101

Aurreview Generac sorgailuak: eramangarriak, etxebizitzarako eta merkataritzarako irtenbideak
Arakatu Generac-en sorgailu sorta zabala, eramangarriak, etxebizitzetarako eta merkataritzarako sistemak barne. Ikasi energia-irtenbide fidagarrien ezaugarriak, zehaztapenak eta aplikazioak.
Aurreview Generac HTS "Wn" Type Automatic Transfer Switch Owner's Manual
Owner's Manual for the Generac HTS "Wn" Type Automatic Transfer Switch, detailing installation, operation, and maintenance for models 600-2600 Amp, 600 Volts.
Aurreview Generac HS Type Automatic Transfer Switch Owner's Manual
Comprehensive owner's manual for Generac HS Type Automatic Transfer Switches (ATS), models 005036-0 (100A) and 004945-1 (200A). Covers installation, operation, safety guidelines, electrical data, diagrams, and warranty information.
Aurreview Generac 60 Hz-ko airez hoztutako sorgailuen instalazio-jarraibideak (16 kW eta 22 kW)
Generac 60 Hz-ko airez hoztutako erreserba-sorgailuen instalazio-gida zehatza (16 kW eta 22 kW-ko modeloak). Desontziratzetik eta kokapenaren hautaketatik hasi eta konexio elektrikoetara eta hasierako abiaraztearainoko urrats garrantzitsuak biltzen ditu, babeskopia-energia fidagarria lortzeko konfigurazio segurua eta egokia bermatuz.
Aurreview Generac 60 Hz Air-Cooled Generators Owner's Manual (10-24 kW)
Comprehensive owner's manual for Generac 60 Hz air-cooled standby generators, covering operation, maintenance, safety, and troubleshooting for models ranging from 10 kW to 24 kW.
Aurreview Generac Guardian Series etxebizitzarako sorgailu autonomoak (20-24 kW) - Ezaugarriak eta zehaztapenak
Arakatu Generac Guardian Series etxebizitzetarako sorgailu autonomoak (20, 22 eta 24 kW). Dokumentu honek ezaugarri nagusiak, True Power™ eta Mobile Link™ bezalako teknologia aurreratuak, zehaztapen osoak eta etxeko energia-kopuru fidagarria lortzeko osagarri bateragarriak zehazten ditu.