Qoltec 50900

QOLTEC 50900 Hiru Faseko Energia Kontsumo Neurgailu Elektronikoaren Erabiltzaile Eskuliburua

1. Sarrera

This manual provides detailed instructions for the installation, operation, and maintenance of the QOLTEC 50900 Three Phase Electronic Energy Consumption Meter. This device is designed for measuring active energy consumption in three-phase, four-wire AC circuits. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Segurtasun informazioa

OHARRA: Installation and maintenance of this device must be performed by qualified personnel only. Failure to follow these instructions can result in electric shock, fire, or serious injury.

3. Produktua amaitu daview

The QOLTEC 50900 is a compact, DIN rail mountable electronic energy meter designed for accurate measurement of three-phase energy consumption. It features an LCD display for clear readings and a pulse output for remote monitoring.

QOLTEC 50900 Energy Meter with dimensions and key features

Figure 3.1: QOLTEC 50900 Energy Meter showing dimensions (75mm x 92mm x 76mm) and key features like Three Phase Type, 230V Rated Voltage, 1.0 Precision Class, and LCD Display.

Ezaugarri nagusiak:

4. Zehaztapenak

ParametroaBalioa
Eredua50900
Balorazio baloratuatage3x230/400V AC
Korronte nominatua3x10(100)A
Maiztasuna50Hz
Zehaztasun Klasea1.0
BistaratzeaLCDa
Pultsuko irteera400 in/kWh
InstalazioaDIN Rail (4P)
Neurriak (W x H x D)75 x 92 x 76 mm
Pisua100 g
MaterialaAkrilikoa

5. Konfigurazioa eta instalazioa

The QOLTEC 50900 meter is designed for standard 35mm DIN rail mounting. Ensure the installation location is dry, well-ventilated, and free from excessive vibration or electromagnetic interference.

5.1 Muntaketa

  1. Locate a suitable 35mm DIN rail within your electrical panel.
  2. Align the meter's DIN rail clip with the rail.
  3. Sakatu neurgailua ondo errailean, bere lekuan klik egin arte.
QOLTEC 50900 Energy Meter mounted on a DIN rail

Figure 5.1: The QOLTEC 50900 meter securely mounted on a DIN rail, showing its compact form factor.

5.2 Kableatutako konexioak

GARRANTZITSUA: All wiring must comply with local electrical codes and regulations. Ensure power is OFF before making any connections.

  1. Identify the input (IN) and output (OUT) terminals on the meter.
  2. Connect the incoming three-phase lines (L1, L2, L3) and Neutral (N) to the corresponding IN terminals (typically 5, 6, 7, 8).
  3. Connect the outgoing three-phase lines (L1, L2, L3) and Neutral (N) to the corresponding OUT terminals (typically 1, 2, 3, 4).
  4. Ziurtatu konexio guztiak estuak eta seguruak direla kontaktu solteak eta gehiegi berotzea saihesteko.
Wiring diagram for QOLTEC 50900 Energy Meter showing input and output terminals

5.2. irudia: Aldea view of the meter showing the wiring diagram for input (IN) and output (OUT) connections for L1, L2, L3, and Neutral.

Front and terminal views of QOLTEC 50900 Energy Meter

5.3. irudia: Aurrealdea view of the meter with its LCD display and a separate view of the terminal block for wiring connections.

6. Funtzionamendu-argibideak

Once properly installed and powered, the QOLTEC 50900 meter will automatically begin measuring energy consumption.

6.1 LCD pantaila

The LCD displays the total active energy consumption in kilowatt-hours (kWh). The display is continuous and does not require any button presses for basic reading.

Close-up of QOLTEC 50900 LCD display showing energy reading

6.1. irudia: hurbileko planoa view of the LCD display showing an example energy reading in kWh.

6.2 Pultsu irteera

The meter features a pulse output (400imp/kWh) which can be used to connect to external monitoring systems for remote data collection. Refer to the external system's documentation for connection details.

7. Mantentzea

The QOLTEC 50900 energy meter is designed for maintenance-free operation under normal conditions.

8. Arazoak

If you encounter issues with your QOLTEC 50900 meter, refer to the following common problems and solutions:

ArazoaKausa posibleaIrtenbidea
No display/Meter not powering onNo power supply; Incorrect wiring; Blown fuse in circuitCheck power supply to the meter. Verify wiring connections. Check circuit breaker/fuse.
Incorrect energy readingIncorrect wiring; Faulty meterVerify wiring connections against the diagram. If wiring is correct, contact support.
Pulse output not workingIncorrect connection to external system; Faulty meterCheck pulse output wiring to the external system. Consult external system's manual. If issue persists, contact support.

If the problem persists after attempting these solutions, please contact Qoltec customer support.

9. Bermea eta Laguntza

Qoltec products are manufactured to high-quality standards. For warranty information and technical support, please refer to the warranty card included with your product or visit the official Qoltec webgunea. Gorde erosketa-agiria erosketaren frogagiri gisa.

Erlazionatutako dokumentuak - 50900

Aurreview Safety Warnings for Use: Qoltec DIN Rail Electricity Consumption Meters (TUYA)
Comprehensive safety warnings and precautions for the installation, use, maintenance, and storage of Qoltec DIN rail electricity consumption meters (TUYA) to ensure user safety and product longevity, compliant with EU regulations.
Aurreview Qoltec DIN Rail Electricity Consumption Meter Safety Warnings and Precautions
Comprehensive safety warnings and precautions for Qoltec DIN rail electricity consumption meters, covering electrical risks, overloading, overheating, misuse, environmental factors, maintenance, and emergency procedures.
Aurreview Qoltec DIN Rail (TUYA) Elektriarvesti Ohutusjuhised
Täielikud ohutusjuhised ja ettevaatusabinõud Qoltec DIN Rail (TUYA) tüüpi elektriarvestite paigaldamiseks, kasutamiseks ja hooldamiseks. Tootja: NTEC sp. z o.o.
Aurreview Qoltec 50882 Single-phase Smart Energy Meter with Wi-Fi - Operating Instructions
Operating instructions for the Qoltec Model 50882, a single-phase smart energy meter with Wi-Fi for DIN rail mounting. Features include remote monitoring, kWh measurement, and compliance with industry standards.
Aurreview Qoltec Three Phase Smart Din Rail Energy Meter wi-fi User Manual
User manual for the Qoltec Three Phase Smart Din Rail Energy Meter wi-fi with 7 modules, model 50883. Includes technical parameters, dimensions, connection instructions, and warranty information.
Aurreview Qoltec DIN errail-energia neurgailuaren (TUYA) segurtasun eta erabilera jarraibideak
Qoltec DIN errailetako energia-neurgailuen (TUYA) segurtasun-neurri eta erabilera-jarraibide osoak. Ikasi arrisku elektrikoei, gainkarga-arriskuei, gehiegi berotzeari, instalazio egokiei, mantentze-lanei eta larrialdi-prozedurei buruz, energia-kontsumoaren monitorizazio segurua eta zehatza bermatzeko.