ProLine 116-502

ProLine 116-502 Gas Ball Valve

Argibide eskuliburua

1. Produktua amaitu daview

The ProLine 116-502 Gas Ball Valve is a forged brass valve designed for reliable shut-off in natural gas or LP gas applications. It features a durable 1-piece body construction and convenient 3/8-inch flare x flare connections. The valve is equipped with a chrome-plated ball and a quarter-turn lever handle for easy operation. This product is CSA 3-88 certified, ensuring compliance with safety and performance standards for gas appliances.

ProLine 116-502 Gas Ball Valve with yellow lever handle and flare connections.

This image displays the ProLine 116-502 Gas Ball Valve, featuring a brass body, a yellow quarter-turn lever handle, and 3/8-inch flare connections on both ends. The valve is designed for gas applications.

2. Segurtasun informazioa

OHARRA: Instalazio, doikuntza, aldaketa, zerbitzu edo mantentze desegokiak kalteak, lesioak edo heriotza eragin ditzakete. Irakurri arretaz instalazio, funtzionamendu eta mantentze-argibideak ekipo hau instalatu edo zaindu aurretik.

  • Always ensure gas supply is turned off before installation or maintenance.
  • Instalazioa profesional kualifikatu batek egin behar du, tokiko araudi eta araudi guztien arabera.
  • Use appropriate tools and personal protective equipment.
  • Check for leaks after installation using a non-corrosive leak detection solution.
  • Do not use open flames to check for gas leaks.
  • This valve is intended for natural gas or LP gas applications only. Do not use for other media.

3. Konfigurazioa eta instalazioa

This section provides general guidelines for the installation of the ProLine 116-502 Gas Ball Valve. Always refer to local plumbing and gas codes for specific requirements.

3.1 Instalazioaren aurreko egiaztapenak

  1. Verify that the valve model 116-502 is suitable for your specific gas application (natural gas or LP gas).
  2. Ensure the connection sizes (3/8-inch flare) match your existing piping.
  3. Inspect the valve for any visible damage before installation. Do not install a damaged valve.
  4. Gather all necessary tools, including wrenches, pipe thread sealant (if applicable for other connections in the system), and leak detection solution.

3.2 Instalazio-urratsak

  1. Turn off Gas Supply: Locate the main gas shut-off valve and turn off the gas supply to the area where the valve will be installed.
  2. Konexioak prestatu: Ensure the flare connections on your gas lines are clean and free of debris.
  3. Connect Valve: Align the valve with the gas lines. Hand-tighten the flare nuts onto the valve's flare connections.
  4. Konexioak estutu: Using appropriate wrenches, carefully tighten the flare nuts. Do not overtighten, as this can damage the flare connections. Refer to manufacturer's recommendations for torque specifications if available, or tighten until snug and then an additional quarter to half turn.
  5. Restore Gas Supply: Slowly turn the main gas supply back on.
  6. Egiaztatu ihesak: Apply a non-corrosive leak detection solution to all new connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately, re-tighten the connection, and re-test. Repeat until no leaks are present.

4. Funtzionamendu-argibideak

The ProLine 116-502 Gas Ball Valve is designed for simple on/off operation.

  • Balbula irekitzeko: Rotate the yellow lever handle 90 degrees (a quarter-turn) so that it is parallel with the gas flow direction.
  • Balbula ixteko: Rotate the yellow lever handle 90 degrees (a quarter-turn) so that it is perpendicular to the gas flow direction.

The quarter-turn design allows for quick and easy visual confirmation of the valve's open or closed status.

5. Mantentzea

The ProLine 116-502 Gas Ball Valve is designed for long-term, maintenance-free operation under normal conditions. Regular inspection is recommended.

  • Aldizkako ikuskapena: Visually inspect the valve and connections periodically for any signs of corrosion, damage, or leaks.
  • Ihesen egiaztapenak: If you suspect a leak, perform a leak check using a non-corrosive leak detection solution.
  • Garbiketa: Clean the exterior of the valve with a damp cloth if necessary. Do not use harsh chemicals or abrasive cleaners.
  • Erabiltzaileak ez du zerbitzurik gabeko piezarik: This valve contains no user-serviceable parts. Do not attempt to disassemble or repair the valve. If the valve is damaged or malfunctioning, it must be replaced by a qualified professional.

6. Arazoak

This section addresses common issues that may arise with gas ball valves. Always prioritize safety and consult a professional for any complex issues.

  • Gas ihesa detektatu da:
    • Sintoma: Smell of gas, or bubbles when leak detection solution is applied.
    • Ekintza: Immediately turn off the main gas supply. Re-check all connections for proper tightening. If the leak persists, do not attempt further repairs. Contact a qualified gas technician.
  • Valve Difficult to Turn:
    • Sintoma: Lever handle is stiff or hard to rotate.
    • Ekintza: Do not force the handle. Excessive force can damage the valve. If the valve is new, it may be slightly stiff initially. If it becomes stiff over time, it may indicate internal wear or debris. The valve should be replaced by a qualified professional.
  • Gas-fluxurik ez:
    • Sintoma: Appliance not receiving gas, even with valve in open position.
    • Ekintza: Ensure the valve handle is fully parallel to the pipe (open position). Check other shut-off valves in the system and the main gas supply. If the issue persists, contact a qualified gas technician.

7. Zehaztapenak

ZehaztapenaXehetasuna
Modelo zenbakia116-502
MarkaProLine
MaterialaForged Brass (Chrome Plated Ball)
Konexio motaFlare x Flare
Konexioaren tamaina3/8 inch x 3/8 inch
FuntzionamenduaQuarter-Turn Lever Handle
Ziurtagiriak3-88 CSA
AplikazioaGas Naturala edo LP Gasa
Elementuaren pisua3.7 kilo (10ko paketearentzat)
Produktuaren neurriak (L x W x H)7.28 x 4.53 x 2.95 hazbete (10ko paketearentzat)
FabrikatzaileaB&K LLC

8. Bermearen informazioa

For specific warranty details regarding the ProLine 116-502 Gas Ball Valve, please refer to the official ProLine website or contact their customer service directly. Warranty terms typically cover manufacturing defects under normal use and service.

9. Bezeroarentzako arreta

If you have any questions, require technical assistance, or need to report an issue with your ProLine 116-502 Gas Ball Valve, please contact ProLine customer support through their official channels. Always provide the model number (116-502) when seeking support.

Kontsulta orokorrak egiteko, bisita dezakezu ProLine brand page on Amazon.