Renogy RIV1230P2-126

Renogy 3000W 12V Pro uhin sinusoidal puruaren inbertsorearen argibideen eskuliburua

Model: RIV1230P2-126

1. Sarrera

The Renogy 3000W 12V Pro Pure Sine Wave Inverter converts 12V DC battery power into stable 110V/120V AC household electricity. This inverter is designed for reliable performance in various applications, including RVs, trucks, and off-grid home energy systems. Key features include a 3000W continuous power output, 6000W peak power, built-in Bluetooth for monitoring, an EcoSleep mode for energy conservation, and a remote controller for convenient operation.

Renogy 3000W 12V Pro Pure Sine Wave Inverter with remote control and cable

Figure 1: Renogy 3000W 12V Pro Pure Sine Wave Inverter with included remote control and communication cable.

2. Segurtasun informazioa

Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electrical shock, fire, or serious injury.

  • The inverter is UL 458 & CSA C22.2 No. 107.1 certified, ensuring compliance with safety and quality standards.
  • Ensure the inverter chassis is properly grounded to prevent electrical hazards.
  • The inverter features pre-charging functionality to ensure a smooth start, protecting both the battery and the inverter from high peak currents during connection.
  • Dual-polarity reverse connection protection is integrated to prevent internal damage in case of accidental misconnection of battery positive and negative terminals. However, always verify correct polarity before making connections.
  • Be aware that the surge capacity of inductive appliances can exceed their continuous rating by 5 to 7 times. Plan your loads accordingly to avoid unexpected shutdowns.
  • Do not expose the inverter to rain, moisture, or excessive dust.
  • Erabili inbertsorea ondo aireztatutako gune batean gehiegi berotzea saihesteko.
Diagram illustrating pre-charging and dual-polarity reverse protection features of the inverter

Figure 2: Inverter security features including pre-charging and dual-polarity reverse protection.

Renogy inverter with GFCI, FCC, and ETL certifications shown, with a boat in the background

Figure 3: Essential safety protections including GFCI, FCC, and ETL certifications.

3. Konfigurazioa

3.1 Muntaketa

Mount the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure there is adequate space around the inverter for proper airflow and cooling.

3.2 DC sarrerako konexioa

Connect the inverter to your 12V battery bank. Use appropriate gauge cables for the power rating. The inverter is equipped with dual-polarity reverse connection protection, but it is crucial to always connect the positive (+) terminal of the inverter to the positive (+) terminal of the battery and the negative (-) terminal of the inverter to the negative (-) terminal of the battery. The pre-charging function will help protect the system during initial connection.

Person connecting battery cables to the inverter, highlighting reverse polarity protection

Figure 4: Connecting battery cables to the inverter, demonstrating reverse polarity protection.

3.3 AC irteerako konexioa

The inverter provides two standard AC sockets and one AC terminal block for connecting your AC loads. Ensure that the total continuous power draw of your appliances does not exceed 3000W. For permanent installations, use the AC terminal block following local electrical codes.

3.4 Remote Controller Connection

Connect the included 16.4ft wired remote controller to the designated port on the inverter. This allows for convenient power control and monitoring from a distance.

Renogy remote controller for the inverter

Figure 5: The Renogy wired remote controller.

4. Funtzionamendu-argibideak

4.1 Piztu/Itzaltzea

To power on the inverter, press the power button on the unit or the remote controller. The indicator lights will confirm operation. To power off, press the button again.

4.2 EcoSleep Mode

The intelligent EcoSleep mode conserves energy by automatically switching the inverter to a low-power sleep state when no load is detected. In this mode, idle power consumption is less than 10W. The inverter will automatically wake up when an AC load is connected or detected.

Renogy inverter with a smartphone displaying EcoSleep mode settings

Figure 6: Inverter operating in EcoSleep mode, showing smartphone monitoring interface.

Renogy inverter installed in an RV with EcoSleep mode indicator

Figure 7: Inverter in an RV setup, demonstrating EcoSleep mode activation.

4.3 Bluetooth monitorizazioa

The inverter features built-in Bluetooth connectivity, allowing for real-time monitoring via a compatible smartphone application. It also supports RV-C connectivity for seamless integration with Renogy One Core/M1 systems, providing enhanced control and convenience.

Smartphone screens displaying the Renogy inverter monitoring application

Figure 8: Real-time monitoring of the inverter via a smartphone application.

Diagram showing the inverter powering various RV appliances like TV, coffee maker, air conditioner, microwave, and portable freezer

9. irudia: Adibample of RV appliances powered by the inverter.

5. Mantentzea

Mantentze-lan erregularrak zure inbertsorearen iraupena eta errendimendu optimoa bermatzen ditu.

  • Mantendu inbertsorea garbi eta hautsik eta hondakinik gabe. Erabili zapi lehor bat garbitzeko.
  • Ensure all electrical connections, especially battery terminals, are tight and free from corrosion.
  • Verify that the ventilation openings are not blocked to allow for proper heat dissipation.
  • The inverter supports multiple battery types including GEL, AGM, SLA, FLD, and Lithium (LI). Ensure your battery settings are correctly configured if applicable.

6. Arazoak

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific error codes or persistent problems, contact Renogy customer support.

  • Potentzia irteerarik ez: Check battery connections for tightness and correct polarity. Verify battery voltage is within the inverter's operating range. Ensure the inverter is powered on.
  • Low AC Output Voltage: Egiaztatu DC sarrerako boltage from the battery. Ensure the load is not exceeding the inverter's continuous power rating.
  • Gainkargaren adierazlea: Reduce the number of connected AC appliances. Disconnect high-power inductive loads that may cause surge spikes.
  • Gehiegizko berotzea: Ensure the inverter is in a well-ventilated area. Clear any obstructions from the cooling fans. Reduce the load if operating in high ambient temperatures.

7. Zehaztapenak

EzaugarriZehaztapena
Ereduaren izena3000W Pure Sine Wave Inverter Pro
Elementuaren eredu-zenbakiaRIV1230P2-126
Etengabeko potentzia irteera3000W
Goiko potentzia irteera6000W
DC sarrerako bolumenatage12V
CA irteera boltage110V/120V
Bihurketa-eraginkortasunaGehienez %90
Karga osoko eraginkortasunaExceeding 87%
Idle Power Consumption (EcoSleep Mode)< 10 W
Distortsio harmoniko osoa (THD)<% 2
AC entxufeak2
AC terminal blokea1
Remote Controller Cable Length16.4 oin
Produktuaren neurriak (L x W x H)19.5 x 9.2 x 4.2 hazbete
Elementuaren pisua16.6 kilo
ZiurtagiriakUL 458, CSA C22.2 No. 107.1, FCC, ETL
Diagram showing the dimensions of the Renogy 3000W Pure Sine Wave Inverter Pro

Figure 10: Inverter dimensions.

Comparison table of Renogy P2 PRO Series vs. Renogy P2 Series inverters

Figure 11: Feature comparison between Renogy P2 PRO Series and P2 Series inverters.

8. Bermea eta Laguntza

8.1 Bermea

The Renogy 3000W 12V Pro Pure Sine Wave Inverter comes with a 3-year warranty. For any issues encountered within this period, please contact Renogy customer support.

8.2 Bezeroarentzako laguntza

Renogy is committed to providing excellent customer service. Support includes:

  • 24-hour prompt response to inquiries.
  • Access to local warehouses in the US for efficient service.
  • Professional technical guidance to assist with installation, operation, and troubleshooting.
Icons representing Renogy customer support features: 24-hour response, local warehouses, professional technical guidance, and 15 years of experience

Figure 12: Renogy customer support services.

Erlazionatutako dokumentuak - RIV1230P2-126

Aurreview Renogy RIV1230P2-126 Pro 3000W 12V Pure Sine Wave Inverter User Manual
Comprehensive user manual for the Renogy RIV1230P2-126 Pro 3000W 12V Pure Sine Wave Inverter with EcoSleep Mode, covering features, specifications, installation, operation, and safety guidelines.
Aurreview Renogy 3000W 12V Pro uhin sinusoidal puruko inbertsorearen erabiltzailearen eskuliburua
Renogy 3000W 12V Pro uhin sinusoidal puruko inbertsorearen erabiltzailearen eskuliburu osoa, instalazioa, funtzionamendua, segurtasun jarraibideak, zehaztapenak eta arazoak konpontzea zehazten dituena. EcoSleep modua dauka energia-eraginkortasunerako.
Aurreview Renogy 12V 3000W Pro Pure Sine Wave Inverter User Manual
User manual for the Renogy 12V 3000W Pro Pure Sine Wave Inverter, providing essential operation, maintenance, and safety information. Learn about product features, disclaimers, and trademarks.
Aurreview Renogy 12V-ko uhin sinusoidal puruko inbertsorearen transferentzia-etengailuarekin erabiltzailearen eskuliburua
Erabiltzailearen eskuliburu honek Renogy 12V-ko uhin sinusoidal puruko inbertsorearen argibide osoak eskaintzen ditu transferentzia-etengailuarekin, 1000W, 2000W eta 3000W modeloetan eskuragarri. Instalazioa, funtzionamendua, segurtasun-neurriak, arazoak konpontzea eta saretik kanpoko aplikazioen zehaztapen teknikoak biltzen ditu.
Aurreview Renogy 12V-ko uhin sinusoidal puruko inbertsorearen nukleo seriea - Ezaugarri teknikoak eta zehaztapenak
Arakatu Renogy 12V-ko uhin sinusoidal puruko inbertsoreen nukleo seriea, potentzia-bihurketa eraginkorra, funtzionamendu isila eta segurtasun-ezaugarri aurreratuak dituena. Saretik kanpoko sistemetarako aproposa. RIV1210PU-126, RIV1220PU-126 eta RIV1230PU-126 modeloen zehaztapen teknikoak barne hartzen ditu.
Aurreview Renogy 12V-ko uhin sinusoidal puruko inbertsorearen transferentzia-etengailuarekin erabiltzailearen eskuliburua
Renogy 12V-ko uhin sinusoidal puruko inbertsoreen (1000W, 2000W, 3000W) erabiltzailearen eskuliburu osoa, transferentzia-etengailuarekin, instalazioa, funtzionamendua, segurtasuna, arazoak konpontzea eta zehaztapenak biltzen dituena.