ACiQ B0DHFF2DKL

ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System User Manual

Model: B0DHFF2DKL

1. Sarrera

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Segurtasun informazioa

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Segurtasun elektrikoa: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Hozgarrien manipulazioa: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Instalazioa: Instalazioa HVAC profesional baimendu batek egin behar du.
  • Babes pertsonalerako ekipamendua: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Ezaugarri nagusiak

  • Inbertsore teknologia: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Eraginkortasun handia: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Eragiketa sorta zabala: Reliable performance from -13°F to 122°F.
  • Funtzionamendu isila: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Osagai iraunkorrak: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Hozgarri ekologikoa: Utilizes R-454B refrigerant.
  • Instalazio malgua: Supports horizontal and vertical air handler installation.
  • Kontrol adimendunak: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Osagaiak baino gehiagoview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Barruko Aire Kudeatzaile Unitatea
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi termostatoa
  • Zirrinduzko babeslea
  • CPS Charging Adapter
  • Hormako Mahuka
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

1. irudia: Amaituview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Konfigurazioa eta instalazioa

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Instalazioaren aurreko egiaztapenak

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Ziurtatu barruko eta kanpoko unitateetarako leku nahikoa, aire-fluxu egokia eta mantentze-lanetarako sarbidea ahalbidetuz.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

2. irudia: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Kanpoko Unitatearen Kokapena

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

3. irudia: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Funtzionamendu-argibideak

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Oinarrizko funtzionamendu moduak

  • Hozte modua: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Berokuntza modua: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Fan modua: Airea berotu edo hoztu gabe zirkulatzen du.
  • Modu automatikoa: Automatically switches between heating and cooling to maintain the set temperature.
ACiQ outdoor unit operating in extreme heat

4. irudia: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

5. irudia: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Kontrol adimendunak

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

6. irudia: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Mantentzea

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Aire-iragazkia ordezkatzea: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Kanpoko Unitatearen Garbiketa: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Drainatze-sistema: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Ikuskapen profesionala: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Arazoak

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Potentziarik gabe: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Berokuntza/Hozte nahikoa ez: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Ezohiko zaratak: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Ur-ihesak: Check condensate drain line for blockages.

9. Zehaztapenak

Dimensions of ACiQ indoor and outdoor units

7. irudia: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

8. irudia: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

9. irudia: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

EzaugarriXehetasuna
Hozteko Ahalmena31,000 BTU/h
Berokuntza Ahalmena30,000 BTU/hr (at 47°F)
SEER2 Balorazioa18.8
HSPF2 Balorazioa9.7
Hozgarri motaR-454B
Barruko Unitatearen Energia Hornidura115/208/230V, 60Hz, 1Ph
Kanpoko Unitatearen Energia Hornidura208/230V, 60Hz, 1F
Hodiaren gehienezko luzera164 oin (50 m)
Max Height Difference82 oin (25 m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Barruko Unitatearen Pisu Netoa128.97 kilo
Kanpoko Unitatearen Pisu Netoa164.02 kilo

10. Bermea eta Laguntza

ACiQ offers a comprehensive warranty for this heat pump system:

  • Piezen bermea: 7 urte
  • Konpresorearen bermea: 12 urte

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webgunea.