Elitech PG-30

Elitech PG-30Pro Digital Pressure Gauge User Manual

Model: PG-30 | Brand: Elitech

1. Sarrera

This manual provides detailed instructions for the proper use and maintenance of the Elitech PG-30Pro Digital Pressure Gauge. This device is designed for accurate pressure measurement in refrigeration and HVAC systems. Please read this manual thoroughly before operation to ensure correct usage and to prevent damage.

Elitech PG-30Pro Digital Pressure Gauge

Figure 1: Elitech PG-30Pro Digital Pressure Gauge. This image displays the front view of the digital pressure gauge, featuring a blue face with a clear LCD screen, power button, 'SET' button, and 'ZERO' button. The 1/8'' NPT connection is visible at the bottom.

2. Produktuaren ezaugarriak

Elitech PG-30Pro Features Overview

2 Irudia: Gainetikview of Elitech PG-30Pro features. This graphic highlights key functionalities such as backlight display, Max/Min value, zeroing, refrigerant support, auto shut-off, and adjustable units.

Elitech PG-30Pro Refrigerant Compatibility

Figure 3: Refrigerant compatibility of the Elitech PG-30Pro. This image illustrates the gauge's ability to work with over 90 types of refrigerants, including R12, R22, R134a, R290, R401A, R403A, R740, R744, R601, R143A, R32, R21, and R1234yf.

3. Konfigurazioa

3.1 Bateriaren instalazioa

  1. Bilatu bateriaren konpartimentuaren estalkia gailuaren atzealdean.
  2. Remove the cover by twisting or sliding it according to the markings.
  3. Sartu bi (2) AAA pila, konpartimentuaren barruan adierazten den polaritate zuzena (+/-) ziurtatuz.
  4. Jarri bateriaren konpartimenduaren estalkia ongi.

3.2 Hasierako konexioa

  1. Ensure the system to which the gauge will be connected is depressurized or isolated.
  2. Carefully thread the 1/8'' NPT fitting of the digital pressure gauge onto the appropriate port of your HVAC or refrigeration system.
  3. Tighten the connection firmly by hand, then use a wrench for a final snug turn to prevent leaks. Do not overtighten.
Elitech PG-30Pro 1/8-inch NPT Fitting

Figure 4: Dimensions and 1/8-inch NPT fitting. This image shows the physical dimensions of the gauge and highlights the 1/8-inch NPT threaded connection for system integration.

4. Funtzionamendu-argibideak

4.1 Piztu/Itzali

4.2 Zero Function

The zero function is used to correct any minor deviations at the zero pressure point before taking a measurement.

Elitech PG-30Pro Zeroing Function

Figure 5: Zeroing function button. This image highlights the 'ZERO' button on the gauge, indicating its use for resetting the pressure reading to zero.

4.3 Changing Units (Pressure/Temperature)

To cycle through available pressure and temperature units:

Elitech PG-30Pro Adjustable Units

Figure 6: Adjustable temperature and pressure units. This graphic illustrates the various units available for both temperature (°C / °F) and pressure (psi, kg/cm², cmHg, bar, kPa, Mpa, kg/cm²).

4.4 Selecting Refrigerants

The gauge has a built-in database of refrigerants for PT comparison.

4.5 Neurketak irakurtzea

Once connected and powered on, the gauge will display the current pressure and corresponding saturation temperature for the selected refrigerant on its LCD screen.

4.6 Max/Min Value Display and Reset

To view the recorded maximum and minimum pressure values:

Elitech PG-30Pro Max/Min Value Display and Reset

Figure 7: Max/Min value display and reset. This image illustrates how the power button is used to cycle through readings and the zero button to reset recorded maximum and minimum values.

4.7 Auto Shut-Off Setting

The gauge features an adjustable auto shut-off time to conserve battery life.

Elitech PG-30Pro Auto Shut-Off Setting

Figure 8: Auto shut-off setting. This image highlights the 'SET' button, used for configuring the automatic power-off duration to save battery life.

5. Mantentzea

5.1 Garbiketa

5.2 Bateria ordezkatzea

5.3 Biltegiratzea

6. Arazoak

ArazoaKausa posibleaIrtenbidea
Neurgailua ez da piztenBateria hutsik edo gaizki instalatutaOrdeztu bateriak, polaritate zuzena ziurtatuz.
Presioaren irakurketa okerraGauge not zeroed; Sensor contamination; Incorrect unit selectedPerform zero function; Clean sensor port if accessible; Verify selected pressure unit.
Display shows 'ALARM' or flashesPressure overloadImmediately disconnect from pressure source. The gauge is operating beyond its specified range.
Atzeko argiak ez du funtzionatzenLow battery; Backlight setting offReplace batteries; Check if backlight can be toggled (refer to operating instructions).

7. Zehaztapenak

ZehaztapenaXehetasuna
Modelo zenbakiaPG-30
Presio-tartea-14.5 eta 500 PSI
Konexio mota1/8'' NPT
Tenperaturaren Deriba±0.04%FS/℃
Hozgarri euskarria87 types built-in
Energia iturria2 x AAA bateria
MaterialaPlastikoa
Produktuaren neurriak (L x W x H)6.3 x 4.72 x 8.27 hazbete
Elementuaren pisua8.89 ontza

8. Bermea eta Laguntza

8.1 Bermearen informazioa

The Elitech PG-30Pro Digital Pressure Gauge comes with a 12 hilabeteko bermea from the date of purchase, covering manufacturing defects and malfunctions under normal use. This warranty does not cover damage caused by misuse, accident, unauthorized modification, or improper installation.

8.2 Laguntza Teknikoa

For technical assistance, troubleshooting, or warranty claims, please contact Elitech customer support. 24/7 US Technician Support is available via email and phone.

Erlazionatutako dokumentuak - PG-30

Aurreview Elitech MS-100 Digital Multifold Gauge erabiltzailearen eskuliburua
Elitech MS-100 neurgailu digitalaren erabiltzailearen eskuliburua, non ezaugarriak, funtzionamendua, zehaztapenak eta mantentze-lanak zehaztuta dauden.
Aurreview Elitech MS-100 Kolektore Digitalaren Neurgailua: Ezaugarriak, Funtzionamendua eta Zehaztapenak
Elitech MS-100 kolektore digitalaren neurgailuaren gida osoa, ezaugarriak, funtzionamendu azkarra, zehaztapen teknikoak, neurriak eta HVAC eta hozte sistemetarako produktuaren xehetasunak biltzen dituena.
Aurreview Elitech MS Serieko kolektore digitaleko neurgailuaren erabiltzailearen eskuliburua
Elitech MS Serieko kolektore digitalaren neurgailuaren erabiltzailearen eskuliburua, produktuaren deskribapena, informazio orokorra biltzen dituena.view, botoien funtzioak, zehaztapenak, hasiera azkarreko gida, funtzionamendu-urratsak, aplikazio adimendunak eta mantentze-lanak.
Aurreview Elitech MS-100 PLUS Kolektore Digital Adimendunaren Neurgailua Erabiltzailearen Eskuliburua
Elitech MS-100 PLUS Smart Digital Manifold Gauge-aren erabiltzailearen eskuliburu osoa, produktuaren aurkezpena, segurtasun-argibideak eta abar biltzen dituena.view, botoien funtzioak, parametro teknikoak eta hozte eta HVAC sistemetarako funtzionamendu azkarreko gida.
Aurreview Elitech MS-800 Serieko Kolektore Digitalaren Neurgailua Erabiltzailearen Eskuliburua eta Zehaztapenak
Elitech MS-800 Serieko kolektore digitalaren tresnaren erabiltzailearen eskuliburu osoa, produktuaren aurkezpena, segurtasun jarraibideak, ingurumenaren babesa, zehaztapen zehatzak eta presio eta tenperatura neurketetarako, euste presio probak eta HVAC eta hozte sistemetarako hozgarri kargatzeko funtzionamendu gida azkarrak biltzen dituena.
Aurreview VGW 760 Wireless Digital Vacuum Gauge User Manual
Comprehensive user manual for the Elitech VGW 760 Wireless Digital Vacuum Gauge, covering overview, features, specifications, operation instructions, cleaning, app usage, warnings, and package contents for HVAC and refrigeration applications.