VEVOR SPT-504-16A

VEVOR 16U Open Frame Network Rack User Manual

Model: SPT-504-16A

1. Sarrera

This manual provides essential instructions for the safe and efficient assembly, operation, and maintenance of your VEVOR 16U Open Frame Network Rack. Please read this manual thoroughly before installation and retain it for future reference. This rack is designed to organize and secure various networking, IT, and AV equipment in both floor-standing and wall-mounted configurations.

2. Segurtasun-argibideak

  • Always ensure the rack is installed on a stable, level surface when floor-standing.
  • When wall-mounting, use appropriate hardware for your wall type and ensure the wall structure can support the rack's weight plus the maximum load capacity.
  • Do not exceed the specified load capacities: 500 lbs (226.8 kg) for floor-standing and 200 lbs (90.7 kg) for wall-mounted configurations.
  • Distribute equipment weight evenly within the rack to maintain stability.
  • Exercise caution when handling heavy equipment. It is recommended to have assistance during assembly and installation.
  • Keep children and pets away from the rack during assembly and operation.
  • Ensure all screws and fasteners are securely tightened before loading equipment onto the rack.

3. Paketearen edukia

Muntaketa hasi aurretik, egiaztatu osagai guztiak daudela:

  • 2 x Trays (Vented Shelves)
  • 1 x Screw Set (Includes self-tapping screws and other fasteners)
  • 1 x Goiko panela
  • 16 x kaiola intxaurrak
  • 1 x lurrerako haria
  • 1 x Erabiltzailearen eskuliburua
  • Main rack frame components (vertical posts, base, etc.)

4. Konfigurazioa eta Muntaketa

Assembly of the VEVOR 16U Open Frame Network Rack is required. Follow these general steps for construction. A power drill with appropriate bits is recommended for tightening self-tapping screws.

  1. Deskonprimitu osagaiak: Kontu handiz atera pieza guztiak paketetik eta jarri gainazal garbi eta lau batean. Egiaztatu paketearen edukiaren zerrendarekin.
  2. Markoa muntatu: Connect the vertical posts to the base and top panels using the provided screws. Ensure all connections are aligned and tightened securely. The rack utilizes self-tapping screws; ensure the screw is started straight and tightened with steady pressure to cut its own threads smoothly.
  3. Instalatu apalategiak: Attach the vented shelves at your desired height using the cage nuts and screws. The rack features pre-drilled square and threaded holes for flexible equipment mounting.
  4. Lurreratzea: Connect the grounding wire to the designated grounding point on the rack for electrical safety.
  5. Muntatzeko aukerak:
    • Zutikako solairua: Place the assembled rack on a stable, level floor. Ensure it is not wobbly before loading equipment.
    • Horman muntatuta: Identify suitable wall studs or use appropriate wall anchors. The rack includes wall mount installation holes. Securely fasten the rack to the wall, ensuring it can support the rack's weight and the maximum wall-mounted load capacity of 200 lbs (90.7 kg). Note that wall mount installation does not extend the depth of the rack.
Image showing the VEVOR 16U Open Frame Network Rack components, including grommet holes, pre-drilled holes, and wall mount installation points.

Figure 1: Rack components and features, highlighting grommet holes for cable routing and wall mount installation points.

Close-up image of the VEVOR 16U Open Frame Network Rack showing the top shelf, sturdy vertical post, and thick materials.

Figure 2: Detail of the rack's construction, emphasizing the top shelf, vertical posts, and material thickness for stability.

5. Funtzionamendu-argibideak

5.1. Ekipoen Instalazioa

  • Install your servers, network equipment, IT equipment, and AV gear into the rack using appropriate mounting hardware (not included unless specified).
  • Ensure equipment is securely fastened to prevent movement or accidental dislodgement.
  • Distribute the weight of your equipment as evenly as possible across the rack units and shelves to maintain balance and stability.

5.2. Karga Ahalmena

Adhere strictly to the following load capacities:

  • Floor-Mounted Load Capacity: Gehienez 500 lb (226.8 kg)
  • Wall-Mounted Load Capacity: Gehienez 200 lb (90.7 kg)
Image illustrating the VEVOR 16U Open Frame Network Rack's load capacities for floor-mounted (500 lbs) and wall-mounted (200 lbs) configurations.

Figure 3: Visual representation of the rack's maximum load capacities for different mounting types.

5.3. Kableen kudeaketa

The top panel of the rack features pre-drilled grommet holes for easy and organized cable routing. Utilize these holes to manage power and data cables, ensuring a tidy and accessible setup. Proper cable management helps maintain airflow and prevents accidental disconnections.

5.4. Kokapenari buruzko gogoetak

This open frame rack is suitable for various environments where space optimization and accessibility are key. It can be used in retail spaces, classrooms, offices, home labs, and other areas requiring organized IT infrastructure.

Image showing the VEVOR 16U Open Frame Network Rack in various settings: office, classroom, and home, demonstrating its versatility.

4. irudia: Adibamples of the rack's application in different environments, promoting tidy cable management.

5.5. Produktuaren bideoa

Video 1: An official product video demonstrating the features and potential uses of the VEVOR 16U Open Frame Network Rack.

6. Mantentzea

  • Garbiketa: Regularly wipe down the rack with a soft, dry cloth to remove dust and debris. Avoid using abrasive cleaners or solvents.
  • Ikuskapena: Periodically check all screws and fasteners to ensure they remain tight. Re-tighten any loose connections to maintain the rack's structural integrity.
  • Load Check: Ensure that the total weight of equipment does not exceed the specified load capacities for your mounting configuration.

7. Arazoak

7.1. Difficulty with Self-Tapping Screws

If you encounter difficulty with the self-tapping screws during assembly:

  • Ensure the screw is aligned perfectly straight with the hole before applying pressure.
  • Apply steady, firm pressure while turning the screw. The screw is designed to cut its own threads into the metal.
  • Using a power drill with a suitable bit at a low speed can assist, but avoid over-tightening.
  • Do not force the screw if it feels misaligned, as this can strip the threads. Remove, realign, and try again.

7.2. Rack Instability

If the rack feels unstable after assembly:

  • Verify that all screws and fasteners are fully tightened.
  • Ensure the rack is placed on a completely level surface (for floor-standing).
  • Check that equipment weight is distributed evenly.
  • For wall-mounted racks, re-verify the security of the wall anchors and mounting points.

8. Zehaztapenak

Diagram showing the dimensions of the VEVOR 16U Open Frame Network Rack, including height, depth, and width, along with key specifications.

Figure 5: Detailed dimensions and key specifications of the 16U Open Frame Network Rack.

EzaugarriZehaztapena
Modelo zenbakiaSPT-504-16A
Altuera16U (31.61 inches / 803 mm)
Sakonera23 hazbete (585 mm)
Standard Mounting Width19 hazbete (482 mm)
Wall-Mounted Load Capacity200 lb (90.7 kg)
Floor-Mounted Load Capacity500 lb (226.8 kg)
MaterialaCarbon Steel (Q235)
Pisu garbia30.64 lb (13.9 kg)
Produktuaren neurriak (L x W x H)20.08 x 23.03 x 31.61 hazbeteko / 510 x 585 x 803 mm
Gailu bateragarriakServer, Network Equipment, IT Equipment, AV Gear
Muntaia BeharrezkoaBai

9. Bermea eta Laguntza

For warranty information, please refer to the documentation included with your purchase or visit the official VEVOR website. For technical support or assistance with parts, please contact VEVOR customer service through their official channels.

Erlazionatutako dokumentuak - SPT-504-16A

Aurreview VEVOR Zerbitzari-euskarri irekiaren erabiltzailearen eskuliburua
VEVOR Open Frame Server Rack-erako erabiltzailearen eskuliburua, muntaketa-argibideak, produktuaren parametroak, paketearen edukia, lurreratzea eta horman muntatzea zehazten dituena. Segurtasun-abisuak eta erantzukizun-mugak barne hartzen ditu.
Aurreview VEVOR Zerbitzari-euskarri erregulagarri irekia erabiltzailearen eskuliburua
VEVOR Erregulagarri den marko irekiko zerbitzari-euskarriaren erabiltzailearen eskuliburua, muntaketa-argibideak, produktuaren diagramak, paketearen edukia, eskakizunak eta segurtasun-abisuak barne. SPT-504-09, SPT-504-12, SPT-504-15 eta SPT-504-20 SKUak biltzen ditu.
Aurreview VEVOR Zerbitzari-euskarri erregulagarri irekiko erabiltzailearen eskuliburua | Instalazioa eta zehaztapenak
VEVOR Erregulagarri diren Egitura Irekiko Zerbitzari-euskarrien (HT-W6412, HT-W6415, HT-W6420) erabiltzailearen eskuliburu osoa. Instalazio-gida, paketearen edukia, segurtasun-abisuak eta produktuaren zehaztapenak barne hartzen ditu.
Aurreview VEVOR SPT-505-09 Hormako Zerbitzari-euskarriaren instalazio-gida
VEVOR SPT-505-09 Hormako Zerbitzari-euskarriaren gida osoa, muntaketa, zehaztapenak eta ekipamendua modu eraginkorrean antolatzeko horman muntatzeko argibideak biltzen dituena.
Aurreview VEVOR Zerbitzari-euskarri erregulagarri irekia erabiltzailearen eskuliburua
VEVOR Erregulagarri den marko irekiko zerbitzari-euskarriaren erabiltzailearen eskuliburua, produktuaren parametroak, paketearen edukia, muntaketa-argibideak eta segurtasun-abisuak barne. HT-W6412, HT-W6415 eta HT-W6420 modeloak hartzen ditu barne.
Aurreview VEVOR SPT-404-06 Wall Mount Server Rack - Secure & Efficient Storage
Discover the VEVOR SPT-404-06 Wall Mount Server Rack, designed for secure and efficient storage of your networking and server equipment. This durable rack offers easy installation and optimal organization. Learn more about its specifications and features.