The ACONEE 12000 BTU 19 SEER Ductless Mini-Split Air Conditioner Heat Pump is a versatile 3-in-1 system designed for efficient cooling, heating, and dehumidifying. This unit is engineered to provide optimal indoor comfort year-round with quiet operation and energy-saving inverter technology.

  • Hozte eta berotze indartsua: 12,000 BTU capacity effectively cools and heats areas up to 1250 sq ft, maintaining temperatures between 61°F and 88°F.
  • 4-in-1 erosotasuna: Offers Cool, Heat, Dry (dehumidifying), and Fan modes for comprehensive climate control.
  • Energia eraginkorra: Features a 19 SEER2 rating and inverter compressor technology for reduced energy consumption.
  • Funtzionamendu isila: Indoor unit operates as low as 23dB(A) in sleep mode, and the outdoor unit at 42 dB(A), ensuring minimal disturbance.
  • Diseinu iraunkorra: Equipped with Gold-fin condenser coils, an anti-corrosive base-pan, and automatic defrost for reliable performance in various weather conditions (-7°F to 122°F).
ACONEE Mini-Split Air Conditioner providing optimal indoor comfort.

Image: ACONEE Mini-Split Air Conditioner maintaining optimal indoor comfort, showing quick cooling to 60°F and heating to 89°F for up to 750-1250 sq.ft.

ACONEE Mini-Split Air Conditioner with 12000 BTU cooling and 12500 BTU heating capacity.

Image: ACONEE Mini-Split Air Conditioner highlighting its dual cooling (12000 BTU) and heating (12500 BTU) functions.

Konfigurazioa eta Instalazioa

Proper installation is crucial for the optimal performance and longevity of your ACONEE Mini-Split system. This section provides an overview of the installation process. It is recommended to consult a professional HVAC technician for installation to ensure safety and compliance with local codes.

Instalazio Bideo Gida

Video: Detailed installation guide for the ACONEE SEER 19 Series split air conditioner, covering indoor and outdoor unit setup, wiring, and vacuum procedures.

Barruko Unitatearen Instalazioa

  1. Prestaketa: Ensure the wall for the indoor unit is hard and firm to prevent vibration. Reserve adequate space: 15cm above the ceiling, 20cm to side walls, and 230-260cm from the floor.
  2. Plaka muntatzea: Drill holes and fasten the pegboard horizontally and vertically using appropriate screws.
  3. Wall Hole: Create a wall hole (typically 60-80mm diameter) for piping, slanting it 5-10 degrees downward. Avoid pre-buried power wires.
  4. Kableatua: Open the indoor unit cover, pass the power cable out from the back, and fix it on the terminal board with a clamp.
  5. Drain Pipe Preparation: Remove the knock-out panel with a knife and remove burrs to ensure proper drainage. Turn the pipe in the desired direction.
  6. Konektatu hodiak: Connect the connecting pipe to the indoor unit. Aim at the pipe center, tighten the taper nut with fingers, then use a torque wrench according to the provided table. Carefully check for any damage to joints. Joints should not be reused after re-flaring.
  7. Isolamendua: Use the insulation sleeve to wrap the joint part of the indoor unit and the connection pipe. Use insulating material to pack and seal the insulation pipe to prevent condensate water generation on the joint part.
  8. Hustuketa mahuka: Connect the water outlet with drain pipes, ensuring the connection pipes, cables, and drain hose are straight. Use plastic cable ties to wrap them, running the pipe sloping downward.
  9. Muntaketa: Put the refrigerant piping out of the wall hole. Hang the indoor unit on the peg board, moving it from left to right to ensure the hook is properly positioned. Push toward the lower left side and the upper right side until the hook is embedded in the slot and makes a click sound.
  10. Seal Wall Hole: To protect piping and wires, install a pipe protecting ring and seal it with putty.

Kanpoko Unitatearen Instalazioa

  1. Lekua: The outdoor unit should fulfill the requirements in the instruction manual regarding space to obstructions (e.g., 50cm above, 30cm to sides, 200cm air out side).
  2. Muntatzeko euskarria: Use at least 6 expansion bolts to fix the mounting brackets firmly on the wall. Ensure the brackets are level.
  3. Unitate Segurua: Jarri kanpoko unitatea euskarrietan. Erabili 4 torloju kanpoko unitatearen oinak euskarrietara lotzeko.
  4. Connect Pipes to Outdoor Unit: Remove the nut from the stop valves. Aim at the pipe center of the stop valve, tighten the taper nut with fingers, then tighten with two wrenches. Ensure to retighten to prevent potential air leakage.
  5. Konexio elektrikoak: Remove the electrical box cover. Connect the cables respectively to the corresponding terminals of the terminal board of the outdoor unit, following the wiring diagram (provided on the unit). If signals are connected to the plug, conduct a butt joint. Remove the grounding screw out of the electric bracket, cover the grounding wire end onto the grounding screw, and screw it into the grounding hole. Fix the cables reliably with fasteners (pressing board). Put the E-parts cover back in its original place and fasten it with screws.
  6. Vacuum Procedure: Before working on the air conditioner, remove the cover of the stop valve. Connect the stop valve, charge hose, manifold, and vacuum pump as per the diagram. Fully open the handle Lo of the manifold valve and apply vacuum for at least 15 minutes. Check that the compound vacuum gauge reads -0.1MPa (-76cmHg). After applying vacuum, fully open the stop valve with a hex wrench. Screw all the caps and tighten them up.

Funtzionamendu-argibideak

Your ACONEE Mini-Split system offers multiple operating modes to suit your comfort needs.

  • Cool modua: Provides powerful cooling to quickly lower room temperatures.
  • Bero modua: Delivers efficient heating, even in cold outdoor conditions.
  • Dry Mode (Dehumidifying): Reduces humidity levels in the room for a more comfortable environment.
  • Fan modua: Airea zirkulatzen du hoztu edo berotu gabe.
  • Tenperatura kontrola: Ezarri nahi duzun tenperatura 61 °F eta 88 °F artean.
  • Lo egiteko modua: Operates at a reduced noise level (as low as 23dB) for undisturbed rest.
  • Tenporizadorearen funtzioa: Utilize the 0-24H timer for scheduled operation.
  • Pantaila itzalita: Option to turn off the display screen for minimal light disturbance.
  • Mututu modua: Further reduces operational sounds for ultra-quiet performance.
ACONEE Mini-Split Air Conditioner in a bedroom, highlighting tranquil night sound sleep features like Sleep Mode, 0-24H Timer, Screen Off, and Mute Mode.

Image: ACONEE Mini-Split Air Conditioner in a bedroom, illustrating features for tranquil night sound sleep, including a noise level of 23dB in Mute Mode.

Mantentzea

Regular maintenance ensures the efficiency and longevity of your ACONEE Mini-Split system.

Iragazkien garbiketa

  1. Sarbide-iragazkiak: Ireki barruko unitatearen aurrealdeko panela.
  2. Kendu iragazkiak: Kontu handiz kendu aire-iragazkiak.
  3. Garbitu iragazkiak: Wash the filters with lukewarm water and a mild detergent. Rinse thoroughly and allow them to air dry completely before reinstallation.
  4. Berriro instalatu iragazkiak: Place the dry filters back into the unit and close the front panel.

Zaintza Orokorra

  • Kanpoko unitatea: The outdoor unit features Gold-fin condenser coils, an anti-corrosive base-pan, and automatic defrost for enhanced durability and reduced maintenance. Keep the area around the outdoor unit clear of obstructions to ensure proper airflow.
  • Denboraldiko egiaztapenak: Before the start of each cooling or heating season, inspect the outdoor unit for any debris or blockages and clean as necessary.

Arazoak konpontzea

This section provides guidance on common issues you might encounter with your ACONEE Mini-Split system.

Ohiko arazoak eta irtenbideak

  • Elektrizitate-ihesa: If you detect any electricity leakage during operation, immediately turn off the power supply to the unit and contact a qualified technician for further examination and repair.
  • Ura drainatzea: During trial operation, pour 500ml of water along the evaporator (about 20 seconds) to check if water drains normally and if there is any leakage around the indoor unit. Ensure the drain hose is clear and properly sloped.
  • Ezohiko zaratak edo usainak: If the unit produces unusual noises or odors, turn it off and contact customer support.
  • Errendimendu murriztua: Check if air filters are clean. Ensure no obstructions are blocking the indoor or outdoor unit's airflow. Verify that the set temperature is appropriate for the room size and conditions.

Garrantzitsua: Do not install or repair the air conditioner by yourself as wrong installation or maintenance may cause electric shock or fire. Please contact a professional technician to save your time and money.

Zehaztapenak

EzaugarriZehaztapena
MarkaACONEE
Modelo zenbakia2vobmC-sJ3J2vRJju_RVQAvdFIdz
Hozte Potentzia12000 unitate termiko britainiar (BTU)
Berokuntza Ahalmena12500 BTU
SEER Eraginkortasuna19 IGARRIA2
liburukiatage230V
Zarata maila (kanpokoa)42 dezibelio
Noise Level (Indoor, Sleep Mode)23 dezibelio
Elementuaren pisua89.3 kilo
Produktuaren neurriak40.39 x 12.56 x 9.02 hazbete
Solairuaren EstalduraGehienez 1250 oin karratu
Ezaugarri bereziakInverter Compressor, 4-in-1 (Cool, Heat, Dry, Fan)
Dakarten osagaiakInstallation Kit (including 10ft pre-flared copper line set)
Table of specifications for ACONEE Mini-Split Air Conditioners, including BTU, refrigerant, airflow, dimensions, weight, and ambient temperature ranges.

Image: Detailed specifications table for various ACONEE Mini-Split models, including BTU, refrigerant type, airflow volume, dimensions, weight, and ambient temperature ranges for both indoor and outdoor units.

Bermea eta Laguntza

ACONEE is committed to providing reliable products and customer satisfaction.

Babes Planak

Zure inbertsioa babesteko, babes-plan luzatuak eros daitezke:

  • 3 Urteko Babes Plana
  • 4 Urteko Babes Plana
  • Babes osoa: Iraganeko eta etorkizuneko erosketak estaltzen dituen hileko plana.

Estaldurari eta baldintzei buruzko xehetasunak lortzeko, kontsultatu babes-plan espezifikoaren dokumentazioa.

Bezeroarentzako Arreta

For any questions, technical assistance, or warranty claims, please contact ACONEE customer support. Contact information can typically be found on the product packaging or the official ACONEE webgunea.