AC Infinity AC-PHM3

AC Infinity pH Meter Kit (Model AC-PHM3) Instruction Manual

Brand: AC Infinity | Model: AC-PHM3

Sarrera

The AC Infinity pH Meter Kit (Model AC-PHM3) is a high-precision digital instrument designed for accurate measurement of water acidity, alkalinity, and temperature. This device assists in optimizing water quality for various applications, including gardening, hydroponics, aquariums, swimming pools, and general water treatment. Its responsive lithium glass membrane sensor provides instant pH readings with a high accuracy of ±0.1 pH. The meter features an IP-67 rating, ensuring protection against moisture, heat, dust, and sand, and includes a sensor shield for probe safeguarding. The kit comes with 4.00 pH and 7.00 pH calibration solutions to maintain consistent accuracy and support proper probe storage.

Kutxan dagoena

  • AC Infinity pH Meter (Model AC-PHM3)
  • 4.00 pH Calibration Solution
  • 7.00 pH Calibration Solution
  • Storage Solution (for probe maintenance)
  • Babes-estalkia

Konfigurazioa

Hasierako Prestaketa

  1. Unpack the Meter: Carefully remove the pH meter and accessories from the protective carrying case.
  2. Probe Hydration: Before first use, and after prolonged storage, soak the pH probe in the provided storage solution for approximately 30 minutes. This hydrates the lithium glass membrane, ensuring optimal performance and accuracy.
  3. Garbiketa-zunda: After hydration, gently rinse the probe with distilled or deionized water. Do not wipe the glass membrane, as this can damage it.

Kalibrazioa

Regular calibration is crucial for maintaining the accuracy of your pH meter. The AC-PHM3 supports 2-point or 3-point calibration using the included 4.00 pH and 7.00 pH solutions. For best results, perform a 3-point calibration (4.00, 7.00, and 10.00 pH if a 10.00 pH solution is acquired separately) or at least a 2-point calibration (4.00 and 7.00 pH) before each critical measurement session or if readings become inconsistent.

  1. Prepare Solutions: Pour small amounts of the 4.00 pH and 7.00 pH calibration solutions into separate, clean containers. Ensure the solutions are at room temperature.
  2. Hasi Kalibrazioa: Turn on the pH meter. Refer to the meter's display for calibration mode instructions, typically activated by pressing a 'CAL' button.
  3. Calibrate with 7.00 pH: Immerse the rinsed probe into the 7.00 pH solution. Allow the reading to stabilize. The meter will typically indicate successful calibration (e.g., a smiley face or 'END').
  4. Calibrate with 4.00 pH: Rinse the probe thoroughly with distilled water. Immerse it into the 4.00 pH solution. Allow the reading to stabilize and confirm calibration.
  5. (Optional) Calibrate with 10.00 pH: If performing a 3-point calibration, rinse the probe and immerse it into a 10.00 pH solution (not included).
AC Infinity pH Meter displaying a 4.00 pH reading and 76.5 degrees Fahrenheit, indicating lab-grade precision.

Image: The AC Infinity pH Meter displaying a stable 4.00 pH reading, demonstrating its precision during calibration.

Funtzionamendu-argibideak

Neurketa bat hartzea

  1. Aktibatu: Press the power button to turn on the pH meter.
  2. Garbiketa-zunda: Always rinse the probe with distilled or deionized water before and after each measurement to prevent cross-contamination.
  3. Murgildu zunda: Dip the pH probe into the sample solution you wish to test. Ensure the liquid level is above the sensor bulb.
  4. Irakurketa egonkortu: Gently stir the probe in the solution and wait for the reading on the display to stabilize. The meter will typically indicate when the reading is stable.
  5. Erregistroaren irakurketa: Note down the pH and temperature values displayed.
  6. Garbitu eta gorde: After measurement, rinse the probe thoroughly with distilled water and place it back into the storage solution or protective cap.
AC Infinity pH Meter submerged in a beaker of liquid, demonstrating its use for water quality testing.

Image: The AC Infinity pH Meter actively measuring the pH of a liquid sample in a beaker.

Understanding the Sensor

The AC-PHM3 utilizes a sensitive lithium glass membrane sensor for rapid and accurate pH detection. This advanced sensor technology allows for quick determination of water's acidity and alkalinity, along with integrated temperature measurement, which is crucial for temperature-compensated pH readings.

Close-up of the AC Infinity pH Meter's lithium glass membrane sensor, highlighting its advanced water testing capability.

Irudia: Xehetasun zehatza view of the lithium glass membrane sensor, the core component for advanced water testing.

Mantentzea

Zunda Garbiketa

To ensure accurate and consistent readings, the pH probe should be cleaned regularly, especially after testing samples that may leave residue. Rinse the probe thoroughly with distilled water. For stubborn deposits, a mild cleaning solution specifically designed for pH probes can be used, followed by a thorough rinse.

Biltegiratzea

Proper storage is vital for extending the lifespan of the pH probe. Always store the probe with its cap filled with the provided storage solution. Never store the probe dry or in distilled water, as this can dehydrate the glass membrane and lead to inaccurate readings or permanent damage.

Recalibration Frequency

The frequency of recalibration depends on usage and the accuracy required. For critical applications or frequent use, recalibrate the meter daily or every few days. For less frequent use, recalibrate at least once a week or whenever readings appear inconsistent. Always recalibrate after cleaning the probe or if the meter has been stored for an extended period.

AC Infinity pH Meter with an IP67 waterproof rating, emphasizing its durability and protection against water and dust.

Image: The AC Infinity pH Meter, showcasing its IP67 rating for enhanced durability and protection during use and maintenance.

Arazoak konpontzea

ArazoaKausa posibleaIrtenbidea
Inaccurate or Unstable Readings
  • Probe not properly hydrated
  • Probe is dirty or contaminated
  • Calibration solutions expired or contaminated
  • Meter not calibrated or improperly calibrated
  • Air bubbles on the probe
  • Soak probe in storage solution for 30 minutes
  • Clean probe with distilled water or pH cleaning solution
  • Use fresh calibration solutions
  • Perform a full 2-point or 3-point calibration
  • Gently tap the meter to dislodge bubbles
Meter Does Not Turn On
  • Bateria gutxi edo agortuta
  • Bateriaren kontaktuak zikinak daude
  • Ordeztu bateriak
  • Garbitu bateriaren kontaktuak
Erantzun-denbora motela
  • Probe is dry or aged
  • s baxuaample tenperatura
  • Re-hydrate probe in storage solution
  • Ziurtatu sample is at room temperature

Zehaztapenak

EzaugarriXehetasuna
Modelo zenbakiaAC-PHM3
Zehaztasuna±0.1 pH Accuracy
Sentsore motapH, Temperature
Zunda motaLithium Glass Membrane
IP balorazioaIP67
Calibration Solutions Included4.00 pH, 7.00 pH
Elementuaren pisua1.96 kilo
Paketearen neurriak11.22 x 8.03 x 3.15 hazbete
Detailed specifications of the AC Infinity pH Meter, including model, dimensions, sensor type, and calibration solutions.

Image: A visual summary of the AC Infinity pH Meter's key specifications and included calibration solutions.

Bermea eta Laguntza

For warranty information, technical support, or assistance with your AC Infinity pH Meter Kit (Model AC-PHM3), please visit the official AC Infinity webwebgunera edo jarri harremanetan bezeroarentzako arreta-zerbitzuarekin. Gorde erosketa-agiria erosketaren frogagiri gisa, berme-erreklamazioetarako.

AC Infinity Ofiziala Webgunea: www.acinfinity.com

Erlazionatutako dokumentuak - AC-PHM3

Aurreview AC Infinity pH Meter PRO User Manual and Guide
User manual for the AC Infinity pH Meter PRO (models AC-PHM3, AC-PHM5, AC-PHM7). Learn about setup, calibration, pH and conductivity measurements, maintenance, troubleshooting, and product features for accurate environmental monitoring in hydroponics and gardening.
Aurreview AC Infinity pH Meter User Manual: Features, Calibration, Maintenance & Troubleshooting
Comprehensive user manual for the AC Infinity pH Meter, covering key features, setup, calibration procedures, measurement techniques, maintenance, troubleshooting guide, and warranty information. Includes model details for AC-PHM3, AC-PHM5, AC-PHM7.
Aurreview AC Infinity IONGRID SERIES Grow Light System User Manual
Comprehensive user manual for the AC Infinity IONGRID SERIES Grow Light System, covering installation, setup, programming, features, and troubleshooting for S-Series and T-Series models.
Aurreview AC Infinity Advance Grow System: Uživatelská příručka pro kompletní sady for interiérové ​​rostliny
Helburua AC Infinity Advance Grow System, oso-osorik egin dezakezu tartean. Tato uživatelská příručka poskytuje podrobné informace o instalaci, konfiguraci a používání stanů, osvětlení, ventilátorů a ovladačů pro automatizované pěstební prostředí.
Aurreview AC Infinity Cloudlab Serieko Hedapen Aurreratuko Karparen Erabiltzaile Eskuliburua
AC Infinity Cloudlab Series Advance Propagation Tentaren erabiltzailearen eskuliburua, ezaugarriak, produktuaren edukia, instalazio urratsak, konfigurazio desberdinak, kontrolatzailearen konfigurazioa, muntaketa aukerak eta bermearen informazioa zehaztuz.
Aurreview AC Infinity Advance Hazkuntza Sistemaren Erabiltzaile Eskuliburua: Barruko Landareen Kit Osoa
AC Infinity Advance Grow System-erako erabiltzailearen eskuliburu osoa, barruko landareentzako kit osoa. Ikasi zure hazkuntza-denda, argi, haizagailu eta kontrolagailuaren konfigurazioa, instalazioa, osagaiak eta programazioa.