ENTTEC 73539 DIN PIXIE
Produktuaren informazioa
Zehaztapenak:
- Protokolo pertsonalizatua sortzeko gida
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
Produktuak erabiltzeko jarraibideak
Sarrera:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
Konfigurazio-baldintzak:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
FIRMWARE BATERAGARRIA
Protokolo pertsonalizatua sortzea ENTTEC pixel kontrolagailu hauetan agertzen da:
| SKU | Produktua | Firmware bertsioa |
| 73539 | DIN PIXIE | V2.0 edo berriagoa |
| 70067 | PIXELATOR MINI | V2.0 edo berriagoa |
| 70068 | PIXELATOR MINI MK2 | V1.0 edo berriagoa |
| 71521 | OCTO MK2 | V4.0 edo berriagoa |
| 71522 | OCTO MK3 | V1.0 edo berriagoa |
SARRERA
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- Ezaugarri honek erabiltzaileei bolumena doitzeko aukera ematen dietagOnartutako protokoloetan oinarritutako denborak datuak transmititzeko metodoa gure onartzen diren protokoloren batekin bat badator.
- Dokumentu honek pixel pertsonalizatutako protokolo bat sortzeko eta irizpideak egiaztatzeko konfiguratzeko argibideak eskaintzen ditu.
KONFIGURATZEKO BALDINTZAK
Protokolo pertsonalizatu bat sortzeko honako hauek behar dira:
- Fitxa teknikoa: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- Gailua: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
PROTOKOLO NATORRIZAZIOA SORTZEKO GIDA
Ezaugarri honek erabiltzaileei datuen bolumena doitzeko aukera ematen dietage timing to meet specific protocol needs. To create a custom protocol:
- Egiaztatu pixel bateragarrien protokoloaren datu-orria.
- Nabigatu Gailuaren Erabiltzaile Interfazera protokolo pertsonalizatuaren eginbidea gaitzeko.
- Doitu pixel-aparatuaren datu bolumenatage denboraren bidez web interfazea fabrikatzailearen datu-orriaren arabera.
1. urratsa: egiaztatu protokolo bateragarriaren datu-orria
- Egiaztatu nahi duzun protokoloaren datuak transmititzeko metodoa datu-orritik.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Metodo ohikoenak bit gehigarririk gabe transmititzen ditu datuak (adibidez, D1-D2-D3…Dn).
Example: WB2812B-ren datu-orritik ateratako informazioa
- Zenbait protokolo, TM1814 bezalakoak, datu gehigarriak sartzen dituzte aurrealdean (adibidez, C1-C2-D1-D2…Dn).
Example: TM1814-ren datu-orritik ateratako informazioa
- Metodo ohikoenak bit gehigarririk gabe transmititzen ditu datuak (adibidez, D1-D2-D3…Dn).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Izendatu gailuak onartzen duen bat-etortze protokoloa (edo aukeratu goiko hauetatikample) that shares the same data transmission method as your desired pixel protocol.
- Joan 2. urratsera konfigurazio gehiagorako.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web interfazea
- Google Chrome gisa iradokitzen da web browser to access the OCTO/PIXELATOR MINI’s web interfazea.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webwww.enttec.com webgunea aplikazioa deskargatzeko.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
Joan nahi duzun pixel-aparatua konektatuta dagoen irteerara. Aukeratu 1. urratsean egiaztatutako transmisio-metodo bera partekatzen duen goitibeherako zerrendako pixel-protokolo bat.
- Enable Custom protocol (Continue to Step 3)
Gaitu 'Pertsonalizatua' koadroa datu-bolumenera atzitzekotage denboraren konfigurazioa. Desmarkatu protokolo pertsonalizatua desgaitzeko.
DIN PIXIErentzat
- Konektatu DIN PIXIE ordenagailu batera USB B mota erabiliz.
- Abiarazi EMU softwarea.
- Bilatu gailua eta egin klik aurkitutako DIN PIXIEren Conf-en.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
3. urratsa: Ezarri bolumen pertsonalizatuatage denbora
- Lotu liburukiarekintagnahi duzun protokoloaren datu-orrian. Protokolo pertsonalizatuak 4 sarrera behar ditu datuak bolumena osatzekotage denboraren doikuntza:
liburukiatage Timing Definition Bit 0 High Time (T0H) Liburukiatag0 kodearako denbora handia behar da. Bit 1 High Time (T1H) Liburukiatag1 kodearako denbora handia behar da. Overall Bit Time: Bolumen osoatage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
Berrezarri ordua Bolumen osoatagDatu-sorta bakoitzaren arteko datu-transmisioa berrezartzeko behar den denbora txikia. 
- Fitxa teknikoa – Datu voltage denboraren informazioa Adibample
WB2818B-ren datu-fitxatik- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage denbora tartea.
- Bete liburukiatagIrteerako ezarpenetako eremu pertsonalizatuan denbora tartea.

GARRANTZITSUA
- ENTTEC recommends taking the median value of the range for the start.
- Erabiltzaileak ezarpenak GORDE beharko ditu aldatutako balioa eragina izan dezan.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
ONDORIOA
- Gida honek ENTTEC hautagarri diren gailuetarako protokolo pertsonalizatu bat nola konfiguratu erakutsi zuen eta nahi dituzun pixelen instalazioen datu-orriaren egiaztatzeko ezagutza teknikoa eman zuen.
- Urrats hauek jarraituz, erabiltzaileek goitibeherako zerrendan aurkitzen ez den pixel pertsonalizatuko protokolo bat sor dezakete, laguntza teknikoaren edo firmware berriaren bertsioaren zain egon gabe. Galderarik baduzu edo informazio egokia aurkitzeko zailtasunak badituzu, jarri harremanetan gure lagunarteko laguntza-taldearekin tokiko bulegoetan.
Ohiko galderak
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web arakatzailea.
Can I create a custom protocol without the datasheet?
It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.
Dokumentuak / Baliabideak
![]() |
ENTTEC 73539 DIN PIXIE [pdf] Argibideen eskuliburua DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE |