The PolarFire® MPF050T, MPF100T, MPF200T, MPF300T, and MPF500T production FPGA devices are subject to the limitations described in this document. This document describes updates about known issues, available limitations, and workarounds. It provides a snapshot of the current validation status for feature sets. The document highlights dependencies that may exist between silicon device revisions and specific support by Libero® SoC software versions. Contact Mikrotxiparen laguntza teknikoa informazio gehiagorako.
1. taula. Gailuen berrikuspenak
| Gailua | Paketea | Berrikuspenak |
| MPF050T, TL, TS, TLS, TC | FCSG325 and FCVG484 | 0, 1 |
| MPF100T, TL, TS, TLS, TC | FCG484, FCVG484, and FCSG325 | 0, 1, 2 |
| MPF200T, TL, TS, TLS, TC | FCG784, FCG484, FCVG484, FCSG536, and FCSG325 | 0, 1, 2 |
| MPF300T, TL, TS, TLS, TC | FCG1152, FCG784, FCG484, FCVG484, and FCSG536 | 0, 1, 2 |
| MPF500T, TL, TS, TLS, TC | FCG1152 and FCG784 | 0, 1 |
Oharra: Ikusi CN19014 for details on revision 1 devices.
2. taula. Gailuaren aukerak
| Gailua | Extended Commercial 0 °C–100 °C | Industrial –40 °C–100 °C | STD | –1 | Transceivers T | Lower Static Power L | Data Security S |
| MPF050T, MPF100T, MPF200T, MPF300T, MPF500T | Bai | Bai | Bai | Bai | Bai | — | — |
| MPF050TL, MPF100TL, MPF200TL, MPF300TL, MPF500TL | Bai | Bai | Bai | — | Bai | Bai | — |
| MPF050TS, MPF100TS, MPF200TS, MPF300TS, MPF500TS | — | Bai | Bai | Bai | Bai | — | Bai |
| MPF050TLS, MPF100TLS, MPF200TLS, MPF300TLS, MPF500TLS | — | Bai | Bai | — | Bai | Bai | Bai |
| MPF050TC, MPF100TC, MPF200TC, MPF300TC, MPF500TC | Bai | Bai | Bai | — | Ez | — | — |
For specifications, see PolarFire FPGA Datasheet.
Errata Deskribapenak eta Konponbideak
Hurrengo atalek gailuen akatsak eta, dagokionean, konponbideak deskribatzen dituzte. Dokumentu honen helburua PolarFire FPGA Datu-orrian edo PolarFire erabiltzaile edo demo gida batean agertzen den informazioarekiko aldaketak edo desbideratzeak deskribatzea da.
The following table lists the specific device errata and the affected PolarFire production devices.
1-1 taula. PolarFire FPGA erraten laburpena
| Deskribapena | MPF050T, TL, TS, TLS, TC | MPF100T, TL, TS, TLS, TC | MPF200T, TL, TS, TLS, TC | MPF300T, TL, TS, TLS, TC | MPF500T, TL, TS, TLS, TC |
| MPF300T-ES bitstream compatibility | N/A | N/A | N/A | * | N/A |
| System controller suspend mode interaction with JTAG | * | * | * | * | * |
| PCIe SECDED ECC reporting counters and interrupts | * | * | * | * | * |
| External VERIFY_DIGEST with POR Digest Check for Fabric Components | * | * | * | * | * |
* indicates that the errata exists for that particular device. Details are discussed in the following
atalak.
For feature clarifications about supported transceiver protocols, see the section Supported Transceiver Protocol Status for Production Devices.
1.1. Bitstream Compatibility
MPF300T-ES bit-jarioak ezin dira erabili aurre-ekoizpeneko (PP) edo ekoizpeneko MPF300T gailuak programatzeko.
1.2. System Controller Suspend Mode Interaction with JTAG
If the system controller’s suspend mode is enabled, device initialization may be interrupted after exiting JTAG programming. As a workaround, reset the device after JTAG programazioa.
1.3. PCIe® SECDED Reporting Defeatured
When ECC is enabled (default) within the PCIe hard IP block, the single error correction and double error detection error reporting counters and interrupt registers show erroneous values.
The following features of the PCIe SECDED are being defeatured:
- Single error correction reporting features
- Double error detection feature
More information about this is available in the change impact analysis document.
1.4. Deprecated Feature: Use of External VERIFY_DIGEST with POR Digest Check for Fabric Components
Gailua Fabric Power-On-Reset (POR) digest egiaztapenerako konfiguratuta dagoenean, ehunaren osagaien VERIFY_DIGEST J bidez egin behar da.TAG/SPI-k hutsegite faltsuak jakinarazi ditzake eta zaharkituta dago. Arazo honek ez du eragiten:
- VERIFY_DIGEST of non-fabric components
- CHECK_DIGEST via system service call
- VERIFY_DIGEST functionality for fabric components when Fabric POR digest check is disabled
For more information, refer to the latest revision of the PolarFire Family FPGA Security User Guide.
Ekoizpen-gailuetarako onartutako transzeptibo-protokoloaren egoera
Transzeptorearen protokoloaren gaitasunak balioztatu eta sendoagoak direla frogatzen da, PolarFire FPGA datu-orrian eta PolarFire familiako transzeptorearen erabiltzailearen gidan zerrendatutako zehaztapenen arabera.
The following table summarizes transceiver protocols and validation status for production devices.
This table does not apply to PolarFire core devices (MPFxxxTC).
2-1 taula. Onartutako igorle-protokoloak
| Transceiver Protocol by Device | MPF050T/MPF100T/ MPF200T/MPF300T/ MPF500T Status |
Xehetasunak |
| SGMII/1000BASE-X | Osatu | Transceiver: 1.25 Gbps with CoreTSE IP core. TxPLL SyncE validation is in progress. Contact the factory. |
| CPRI | Osatu | Support for CPRI data rates 1–7 and 7A, 8, 9. |
| 10GBASE-R | Osatu | Transceiver: 10.3125 Gbps with Core10GMAC IP core. TxPLL SyncE is supported. IEEE® 1588 time stamping ez da onartzen. |
| 10GBASE-KR | Osatu | Contact Microchip for a complete solution. |
| Interlaken | Osatu | — |
| JESD204B | Osatu | Up to 12.5G with CoreJESD20BTX/RX IP core. |
| PCIE Endpoint Gen1/Gen2 | Osatu | — |
| PCIE Rootport Gen1/Gen2 | Osatu | — |
| LiteFast | Osatu | Up to 12.7 Gbps (8b10b only). |
| XAUI | Osatu | — |
| RXAUI | Osatu | — |
| HiGig/HiGig+ | Osatu | — |
| Bistaratzeko ataka | Osatu | Per VESA DisplayPort Standard 1.2a. |
| SRIO | Osatu | — |
| PMA only | Osatu | — |
| SATA | Osatu | Jarri harremanetan fabrikarekin. |
| Fiber channel | Osatu | Tested for electrical compliance. |
| SDI | Osatu | HD-SDI (1.485 Gbps) and 3G-SDI (2.970 Gbps) are supported. SD-SDI (270 Mbps) is supported. 6G-SDI and 12G-SDI are supported. |
| OTN | Osatu | Tested for electrical compliance. |
| QSGMII | Osatu | — |
| USXGMII | Osatu | — |
| CoaXPress | Osatu | Tested with external PHY. |
| SLVS-EC | Osatu | — |
| Half-duplex (independent Rx/Tx) | Osatu | — |
Berrikuspen historia
Berrikuspen historiak dokumentuan ezarri ziren aldaketak deskribatzen ditu. Aldaketak
berrikuspenaren arabera zerrendatzen dira, argitalpen berrienetik hasita.
| Berrikuspena | Data | Deskribapena |
| B | 08/2025 | • Added MPF050T and TC information throughout the document. • Eguneratua 1. taula. Gailuen berrikuspenak. • Deprecated Feature: Use of External VERIFY_DIGEST with POR Digest Check for Fabric Osagaiak. • Noted that 2-1 taula. Onartutako igorle-protokoloak does not apply to PolarFire core devices (MPFxxxTC). |
| A | 01/2024 | • Defeatured PCIe SECDED reporting. More information about this is available in the change impact analysis document. • Added references to MPF050T in Erraten Laburpena eta Supported Transceiver Protocols. • Updated to Microchip template. • Updated document number from ER0218 to DS80001111. |
| 6.0 | 05/2021 | • Updated details for SGMII/1000BASE-X row in Table 4 Supported Transceiver Protocols. |
| 5.0 | 12/2020 | • Removed information for “Dynamic Training of HSIO/GPIO IOD Interfaces” and “Temperature-Voltage Sentsorearen (TVS) Tenperatura Banderen Balioak”. • Updated status for SDI, SLVS-EC, and Half-duplex (independent Rx/Tx) to “Complete”. • “SD-SDI (270 Mbps)” and “6G-SDI and 12G-SDI” are supported. • Deleted “Enhanced Receiver Management (ERM) is not supported”. |
| 4.0 | 12/2019 | • Removed MIPI D-PHY support information. For MIPI D-PHY support information, see the PolarFire Datasheet Revision 1.7. • Added Temperature-Voltage Sentsorearen (TVS) informazioa (CN19030 arabera). • Added system control suspend mode interaction with JTAG. |
| 3.0 | 09/2019 | • Removed memory interface limitation from errata for production silicon using Libero SoC version 12.0 or later software. • Removed IOCDR limitations from errata for production silicon using Libero SoC version 12.1 or later software. • Removed RxPLL behavior and DFE calibration limitations from errata for production silicon using Libero SoC version 12.1 or later software using PF_XCVR_ERM core. • Removed errata on the IBIS-AMI DFE support. The released IBIS-AMI models offer full feature support. |
| 2.0 | 11/2018 | • MPF100T device offerings were added. |
| 1.0 | 11/2018 | • It was the first publication of this document, including the MPF200T and MPF300T device offerings. |
Mikrotxiparen informazioa
Markak
"Microchip" izena eta logotipoa, "M" logotipoa eta beste izen, logotipo eta marka batzuk Microchip Technology Incorporated-en edo bere afiliatuen eta/edo filialen marka komertzialak dira Estatu Batuetan eta/edo beste herrialde batzuetan ("Microchip Markak”). Mikrotxiparen markei buruzko informazioa hemen aurki daiteke https://www.microchip.com/en-us/about/legalinformation/microchip-trademarks.
ISBN: 979-8-3371-1825-3
Lege Oharra
This publication and the information herein may be used only with Microchip products, including to design, test, and integrate Microchip products with your application. Use of this information in any other manner violates these terms. Information regarding device applications is provided only for your convenience and may be superseded by updates. It is your responsibility to ensure that your application meets your specifications. Contact your local Microchip sales office for additional support or obtain additional support at www.microchip.com/en-us/support/design-help/client-support-services.
THIS INFORMATION IS PROVIDED BY MICROCHIP “AS IS”. MICROCHIP MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, STATUTORY OR OTHERWISE, RELATED TO THE INFORMATION, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY, AND FITNESS FOR A PARTICULAR PURPOSE, OR WARRANTIES RELATED TO ITS CONDITION, QUALITY, OR PERFORMANCE.
IN NO EVENT WILL MICROCHIP BE LIABLE FOR ANY INDIRECT, SPECIAL, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL LOSS, DAMAGE, COST, OR EXPENSE OF ANY KIND WHATSOEVER RELATED TO THE INFORMATION OR ITS USE, HOWEVER CAUSED, EVEN IF MICROCHIP HAS BEEN ADVISED OF THE POSSIBILITY OF THE DAMAGES ARE FORESEEABLE. TO THE FULLEST EXTENT ALLOWED BY LAW, MICROCHIP’S TOTAL LIABILITY ON ALL CLAIMS IN ANY WAY RELATED TO THE INFORMATION OR ITS USE WILL NOT EXCEED THE AMOUNT OF FEES, IF ANY, THAT YOU HAVE PAID DIRECTLY TO MICROCHIP FOR THE INFORMATION.
Microchip gailuak bizi-euskarri eta/edo segurtasun-aplikazioetan erabiltzea eroslearen arriskuan dago guztiz, eta erosleak onartzen du Microchip-a babestu, indemnizatu eta kalterik gabe uztea erabilera horren ondoriozko kalte, erreklamazio, auzi edo gastuetatik. Ez da lizentziarik ematen, inplizituki edo bestela, Microchip-en jabetza intelektualeko eskubideen arabera, kontrakoa adierazten ez bada.
Mikrotxip gailuen kodea babesteko eginbidea
Kontuan izan Microchip produktuen kodea babesteko funtzioaren xehetasun hauek:
- Mikrotxiparen produktuek beren Mikrotxiparen datu-orrian jasotako zehaztapenak betetzen dituzte.
- Microchip-ek uste du bere produktuen familia segurua dela aurreikusitako moduan erabiltzen denean, funtzionamendu-zehaztapenen barruan eta baldintza normaletan.
- Mikrotxipak bere jabetza intelektualaren eskubideak baloratzen ditu eta modu oldarkorrean babesten ditu. Microchip produktuen kodea babesteko eginbideak hausten saiatzeak erabat debekatuta daude eta Digital Millennium Copyright Acta urratu dezakete.
- Ez Microchip-ek ez beste edozein erdieroale fabrikatzaileek ezin dute bermatu bere kodearen segurtasuna. Kodeen babesak ez du esan nahi produktua "haustezina" denik bermatzen dugunik. Kodeen babesa etengabe garatzen ari da. Microchip-ek gure produktuen kodea babesteko funtzioak etengabe hobetzeko konpromisoa hartzen du.
Erratea
© 2024-2025 Microchip Technology
Inc. and its subsidiaries
Dokumentuak / Baliabideak
![]() |
MICROCHIP MPF050T PolarFire FPGA Zirkuitu Integratuak [pdfErabiltzailearen gida MPF050T, MPF050T PolarFire FPGA Zirkuitu Integratuak, PolarFire FPGA Zirkuitu Integratuak, FPGA Zirkuitu Integratuak, Zirkuitu Integratuak |