Omada L3 Campus Stackable Managed Switch User Manual

L3 Campus Stackable Managed Switch

Zehaztapenak

  • Modeloa: Omada Campus Stackable L3 Managed Switch
  • Front Panel: Mode Selection Button, Management Port, LED,
    Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
    LED
  • LED Adierazpena:
    • PWR1*: Green On (switch powered by PWR1), Off (PWR2
      disconnected or not working properly)
    • PWR2: Green On (switch powered by PWR1 and PWR2 connected),
      Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
      behar bezala)
    • LED SYS FAN: Green On (all fans work properly), Yellow On (not
      all fans work properly)
    • MGMT: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)
    • MST: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)

Produktuak erabiltzeko jarraibideak

2. kapitulua: Instalazioa

Instalazio-prozesua hasi aurretik, ziurtatu guztia duzula
the necessary tools and follow safety precautions.

  • Paketearen edukia: Check all items mentioned in
    paketea.
  • Segurtasun neurriak: Jarraibideei jarraitu
    instalazio segurua bermatzea.
  • Instalazio tresnak: Gather all tools required
    instalatzeko.
  • Produktuen instalazioa: Jarraitu urratsez urrats
    instructions provided in the manual for successful
    instalazioa.

3. kapitulua: konexioa

After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.

4. kapitulua: Konfigurazioa

Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
beharrak.

Ohiko galderak

Q: What should I do if the LED indications show an error?

A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
eskuliburuko atalean laguntza gehiago jasotzeko.

Loading PDF…
Download PDF

Negozio Sareen Konponbidea
Instalazio Gida
Omada C.ampus Stackable L3 Managed Switch

Instalazio gida honi buruz
Instalazio-gida honek hardwarearen ezaugarriak, instalazio-metodoak eta instalazioan zehar zaindu beharreko puntuak deskribatzen ditu. Instalazio-gida hau honela egituratuta dago: 1. kapitulua Sarrera Kapitulu honek etengailuaren kanpoko osagaiak deskribatzen ditu. 2. kapitulua Instalazioa Kapitulu honek etengailua nola instalatu azaltzen du. 3. kapitulua Konexioa Kapitulu honek etengailuaren konexio fisikoa nola egin azaltzen du. 4. kapitulua Konfigurazioa Kapitulu honek etengailua nola konfiguratu erakusten du. A eranskina Arazoak konpontzeko eranskina B zehaztapenak

Publikoa

Instalazio gida hau hauetarako da:

Sareko ingeniaria

Sare-administratzailea

Hitzarmenak
· Gida honetan agertzen diren modelo batzuk zure herrialdean edo eskualdean erabilgarri ez egotea gerta daiteke. Tokiko salmenten informazioa lortzeko, bisitatu https://www.omadanetworks.com/.
· 2. kapituluko, 3. kapituluko eta 4. kapituluko zifrak erakustaldietarako soilik dira. Baliteke zure etengailua irudian dagoenaren itxura desberdina izatea.
· PoE aurrekontuaren kalkuluak laborategiko probetan oinarritzen dira. Benetako PoE potentzia aurrekontua ez dago bermatuta eta bezeroen mugen eta ingurumen-faktoreen ondorioz aldatuko da.
· Gida honek formatu zehatzak erabiltzen ditu mezu bereziak nabarmentzeko. Hurrengo taulan gida honetan erabiltzen diren oharren ikonoak zerrendatzen dira.

Gogoratu kontuz ibili behar dela. Kontuz gero gailuak kalteak sor ditzakeen balizko bat adierazten da.
Gogoratu ohartarazteko. Oharrak produktua hobeto erabiltzeko informazio lagungarria dauka.

Lotutako dokumentua
Deskarga Zentroan eskaintzen dira produktuaren Erabiltzaile-gida eta CLI-ren erreferentzia-gida. Produktuari buruzko azken informazioa lortzeko, bisitatu ofiziala webgunea: https://support.omadanetworks.com/document/.

Edukiak
1. kapitulua Sarrera ———————- 01
1.1 Produktua gainditzeaview …………………………………………………..01 1.2 Itxura………………………………………………………………..01
2. kapitulua Instalazioa ———————- 12
2.1 Paketearen edukia ………………………………………………………….12 2.2 Segurtasun-neurriak …………………………………………………12 2.3 Instalazio-tresnak……………………………………………………..14 2.4 Produktuen instalazioa ………………………………………………..14
3. kapitulua Konexioa ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
4. kapitulua Konfigurazioa ——————– 27
4.1 Konfigurazioa amaituview………………………………………… 27 4.2 Modu autonomoa…………………………………………………… 27 4.3 Kontrolagailuaren modua…………………………………………………… 28
A eranskina Arazoak konpontzeko —————- 32
B eranskina Zehaztapenak —————— 33

Omada C.ampus Stackable L3 Managed Switch

1. kapitulua Sarrera

1.1 Produktua gainditzeaview
Enpresentzat eta c-rentzat diseinatuaampus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Exampsareko kamerak, haririk gabeko LAN sarbide-puntuak, IP telefonoak, sare-zentroak, txertatutako ordenagailuak etab.
1.2 Itxura
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Modu hautatzeko botoia
Kudeaketa Portua

LED

Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 ataka

10G SFP+ Slot LED

The front panel of S6500-48G6XF is shown as the following figure.
Modu hautatzeko botoia
Kudeaketa Portua

LED

Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 ataka

10G SFP+ Slot LED

Sarrera 01

Omada C.ampus Stackable L3 Managed Switch

LED Adierazpena

PWR1*

PWR2

Berdea piztuta

Desaktibatuta

Berdea piztuta

Horia piztuta**

Desaktibatuta

Berdea piztuta

Desaktibatuta

Desaktibatuta

Adierazpena
Etengailua PWR1-ek elikatzen du. PWR2 deskonektatuta dago edo gaizki funtzionatzen du.
Etengailua PWR1-ek elikatzen du. PWR1 eta PWR2 konektatuta daude.*
Etengailua PWR2-ek elikatzen du. PWR1 deskonektatuta dago edo gaizki funtzionatzen du.
Etengailua itzalita dago edo PWR1 eta PWR2 biak gaizki funtzionatzen dute.

LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(STK LEDa piztuta dagoenean)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***

Adierazpena
Keinuka: etengailuak behar bezala funtzionatzen du. Aktibatu edo desaktibatuta: etengailuak gaizki funtzionatzen du.
Berdea piztuta: haizagailu guztiek behar bezala funtzionatzen dute. Horia piztuta: zale guztiek ez dute behar bezala funtzionatzen.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Berdea aktibatuta: 1000 Mbps-an exekutatzen da, baina jarduerarik ez. Berdea keinuka: 1000 Mbps-an exekutatzen eta datuak transmititzen edo jasotzen. Horia aktibatuta: 10Mbps/100 Mbps-an exekutatzen ari da, baina jarduerarik ez. Horia keinuka: 10Mbps/100 Mbps-ra exekutatzen eta datuak transmititzen edo jasotzen. Desaktibatuta: ez dago gailurik dagokion atakarekin lotuta.
Aktibatuta: ataka-zenbakiak unitatearen IDa adierazten du pila-topologian.
Berdea aktibatuta: 10 Gbps-ko abiaduran dabil, baina jarduerarik ez. Berdea keinuka: 10 Gbps-ra exekutatzen eta datuak transmititzen edo jasotzen. Horia piztuta: 1 Gbps-ko abiaduran dabil, baina jarduerarik ez. Horia keinuka: 1 Gbps-ko abiaduran eta datuak transmititzen edo jasotzen. Desaktibatuta: ez dago gailurik dagokion atakarekin lotuta.

*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
** PWR1 eta PWR2 biak ondo funtzionatzen dutenean eta etengailua PWR1-ek elikatzen duenean, 10-20 segundo behar ditu LED PWR2 (horia) itzaltzeko PWR2 deskonektatu ondoren.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

02 Sarrera

Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.

Modu hautatzeko botoia
Kudeaketa Portua
LED Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 ataka

10G SFP+ Slot LED

S6500-48GP6XF-ren aurrealdeko panela hurrengo irudian ageri da.

Modu hautatzeko botoia
Kudeaketa Portua
LED Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 ataka

10G SFP+ Slot LED

The front panel of S6500-24M4Y is shown as the following figure.

Modu hautatzeko botoia
Kudeaketa Portua
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 ataka

25G SFP28 Slot LED

The front panel of S6500-24MPP4Y is shown as the following figure.

Modu hautatzeko botoia
Kudeaketa Portua
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 ataka

25G SFP28 Slot LED

Sarrera 03

Omada C.ampus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.

Modu hautatzeko botoia
Kudeaketa Portua

LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 ataka

The front panel of S6500-48MPP6Y is shown as the following figure.

25G SFP28 Slot LED

Modu hautatzeko botoia
Kudeaketa Portua
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 ataka

25G SFP28 Slot LED

LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST

Adierazpena
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Keinuka: etengailuak behar bezala funtzionatzen du. Aktibatu edo desaktibatuta: etengailuak gaizki funtzionatzen du.
Berdea piztuta: haizagailu guztiek behar bezala funtzionatzen dute. Horia piztuta: zale guztiek ez dute behar bezala funtzionatzen.
Piztuta: gainerako PoE potentzia 7 W-koa da. Keinuka: gainerako PoE potentziak 7 W mantentzen ditu LED hau 2 minutuz piztuta egon ondoren. Desaktibatuta: gainerako PoE potentzia > 7 W da.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.

04 Sarrera

Omada C.ampus Stackable L3 Managed Switch

LED

Adierazpena

Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)

Berdea aktibatuta: 1000 Mbps-an exekutatzen da, baina jarduerarik ez. Berdea keinuka: 1000 Mbps-an exekutatzen eta datuak transmititzen edo jasotzen. Horia aktibatuta: 10Mbps/100 Mbps-an exekutatzen ari da, baina jarduerarik ez. Horia keinuka: 10Mbps/100 Mbps-ra exekutatzen eta datuak transmititzen edo jasotzen. Desaktibatuta: ez dago gailurik dagokion atakarekin lotuta.

Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)

Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(STK LEDa piztuta dagoenean)

Aktibatuta: ataka-zenbakiak unitatearen IDa adierazten du pila-topologian.

Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(PoE LEDa piztuta dagoenean)

Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port

Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***

Berdea aktibatuta: 10 Gbps-ko abiaduran dabil, baina jarduerarik ez. Berdea keinuka: 10 Gbps-ra exekutatzen eta datuak transmititzen edo jasotzen. Horia piztuta: 1 Gbps-ko abiaduran dabil, baina jarduerarik ez. Horia keinuka: 1 Gbps-ko abiaduran eta datuak transmititzen edo jasotzen. Desaktibatuta: ez dago gailurik dagokion atakarekin lotuta.

Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***

Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

Sarrera 05

Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Kudeaketa Portua

LED

Console Port USB3.0 Port

(RJ45/Type-C)

Modu hautaketa

Botoia

10G SFP+ Slot (Port 1-26)

The front panel of S7500-48XF4C is shown as the following figure.

LED 25G SFP28 Slot (Port 27-32)

Modu hautatzeko botoia
Kudeaketa Portua
LED Console Port USB3.0 Port (Type-C/RJ45)

10G SFP+ Slot (Port 1-48)

The front panel of S7500-24Y4C is shown as the following figure.

100G QSFP28 Slot LED (Port 49-52)

Kudeaketa Portua

LED

USB 3.0 ataka

Kontsolaren ataka

(RJ45/Type-C)

Modu hautatzeko botoia

25G SFP28 zirrikitua

LED

(1-24 ataka)

The front panel of S7500-48Y8C is shown as the following figure.

100G QSFP28 Slot (Port 25-28)

LED Mode Selection Button

25G SFP28 Slot (Port 1-48)

06 Sarrera

100G QSFP28 Slot (Port 49-56)

Omada C.ampus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.

Modu hautatzeko botoia
Kudeaketa Portuaren LEDa
USB 3.0 ataka

Console Port (Type-C/RJ45)

100G QSFP28 zirrikitua

LED

Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.

LED Indication LED
PWR1* PWR2
SISTEMAKO HAIZALA
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(SPD LEDa piztuta dagoenean)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)

Adierazpena
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Keinuka: etengailuak behar bezala funtzionatzen du. Aktibatu edo desaktibatuta: etengailuak gaizki funtzionatzen du.
Berdea: haizagailu guztiek behar bezala funtzionatzen dute. Horia: zale guztiek ez dute behar bezala funtzionatzen.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
Oharra:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Berdea aktibatuta: 10 Gbps-ko abiaduran dabil, baina jarduerarik ez. Berdea keinuka: 10 Gbps-ra exekutatzen eta datuak transmititzen edo jasotzen. Horia piztuta: 1 Gbps-ko abiaduran dabil, baina jarduerarik ez. Horia keinuka: 1 Gbps-ko abiaduran eta datuak transmititzen edo jasotzen. Desaktibatuta: ez dago gailurik dagokion atakarekin lotuta.
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Sarrera 07

Omada C.ampus Stackable L3 Managed Switch

LED

Adierazpena

Port 27-32 of S7500-26XF6Y ***
(SPD LEDa piztuta dagoenean)

Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)

Berdea aktibatuta: 100 Gbps-ko abiaduran dabil, baina jarduerarik ez. Berdea keinuka: 100 Gbps-ra exekutatzen eta datuak transmititzen edo jasotzen. Horia piztuta: 40 Gbps-ko abiaduran dabil, baina jarduerarik ez. Horia keinuka: 40 Gbps-ko abiaduran eta datuak transmititzen edo jasotzen. Desaktibatuta: ez dago gailurik dagokion atakarekin lotuta.
Oharra:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)

Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(STK LEDa piztuta dagoenean)

Aktibatuta: ataka-zenbakiak unitatearen IDa adierazten du pila-topologian.

*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Management Port Designed to connnect the device for management through web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.

08 Sarrera

Omada C.ampus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature

Eredua

1000M

2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB

RJ45 Port RJ45 Port Slot

Zirrikitua

Zirrikitua

Portua

Portua Portua

S6500-24G4XF

24

/

4

/

/

S6500-48G6XF

48

/

6

/

/

S6500-24GP4XF

24

/

4

/

/

S6500-48GP6XF

48

/

6

/

/

S6500-24M4Y

/

24

/

4

/

S6500-24MPP4Y

/

24

/

4

/

S6500-48M6Y

/

48

/

6

/

S6500-48MPP6Y

/

48

/

6

/

S7500-26XF6Y

/

/

26

6

/

S7500-48XF4C

/

/

48

/

4

S7500-24Y4C

/

/

/

24

4

S7500-48Y8C

/

/

/

48

8

S7500-32C

/

/

/

/

32

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Security Slot Grounding Terminal Power Socket

Locking Strap Slot

Oharra: PWR1 elikatze-hornidura nagusia da eta lehentasuna du PWR2 baino.

Sarrera 09

Omada C.ampus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington segurtasun zirrikitua

LED

Lurreko terminalera

Power Supply Module

LED

Locking Strap Slot

Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Lurreko terminalera

LED

Power Supply Module Locking Strap Slot

LED

Kensington segurtasun zirrikitua

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.

S7500-48Y8C-ren atzeko panela hurrengo irudian ageri da. Irudia erakustaldi helburuetarako soilik da. Baliteke zure etengailua itxuraz desberdina izatea irudikatutakoarekin alderatuta.

Lurreko terminalera

LED

LED

Blokeatzeko uhala

Zirrikitua

Power Supply Module

10 Sarrera

ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED

Omada C.ampus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

LED LED
Locking Strap Slot
Power Supply Module Kensington Security Slot

Lurreko terminalera

LED
Locking Strap Slot

Power Supply Module

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.

Sarrera 11

Omada C.ampus Stackable L3 Managed Switch

2. kapitulua Instalazioa

2.1 Paketearen edukia

Ziurtatu paketeak honako elementu hauek dituela. Mesedez, jarri harremanetan zure banatzailearekin, zerrendatutako elementuren bat hondatuta badago edo falta bada. Zifrak erakustaldirako soilik dira. Benetako elementuak irudikatutakoaren itxuran eta kantitatean desberdinak izan daitezke.

Aldatu

Elikatze-kablea eta kontsola-kablea

Instalazio Gida
Negozio Sareen Konponbidea
Instalazio Gida
Omada C.ampus Stackable L3 Managed Switch

Muntatzeko euskarriak, torlojuak eta gomazko oinak

2.2 Segurtasun-neurriak
Erabilera desegokiaren ondorioz gailua kaltetu eta gorputzeko lesiorik ez izateko, arau hauek bete behar dituzu.
Segurtasun neurriak Instalazioan zehar, itzali korrontea. Erabili ESD prebenitzeko eskumuturreko uhala eta ziurtatu uhalak azalarekin kontaktu ona duela eta ondo funtzionatzen duela.
ondo lurrera konektatuta. Erabili etengailuarekin batera datorren kablea soilik. Ziurtatu hornidura-bolumenatage bat dator atzeko panelean adierazitako zehaztapenekin
etengailua. Ziurtatu etengailua ondo aireztatutako ingurune batean instalatuta dagoela eta bere aireztapen-zuloa ez dagoela
blokeatuta. Ez ireki edo kendu etengailuaren estalkia. Gailua garbitu aurretik, moztu elikadura iturria. Ez garbitu ur-oihalarekin, eta inoiz ez
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Gunearen eskakizunak
Tenperatura/Hezetasuna

12 Instalazioa

Omada C.ampus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Etengailuan metatutako hautsa elektrizitate estatikoak xurga dezake eta metalezko ukipen-puntuen kontaktu txarra eragin dezake. Neurri batzuk hartu dira gailuak elektrizitate estatikoa saihesteko, baina elektrizitate estatiko indartsuegiak kalte larriak eragin ditzake barne-zirkuitu plakako elementu elektronikoetan. Etengailuaren funtzionamenduan elektrizitate estatikoaren eragina saihesteko, eman garrantzi handia elementu hauei: Gailuari hautsa erregularki kendu eta barruko airea garbi mantendu. Mantendu gailua ondo lurretik eta ziurtatu elektrizitate estatikoa transferitu dela. Interferentzia elektromagnetikoa
Gailuko kapazitatea eta induktantzia barne elementu elektronikoek kanpoko interferentziak eragin ditzakete, hala nola, kapazitate-akoplamenduaren bidezko igorpena, induktantzia-akoplamendua eta inpedantzia-akoplamendua. Interferentziak murrizteko, ziurtatu neurri hauek hartzen dituzula: Erabili sare elektrikoko interferentziak eraginkortasunez iragazten dituen elikadura iturria. Mantendu gailua maiztasun handiko eta korronte handiko gailuetatik, hala nola irrati-transmisioak
geltokia. Erabili blindaje elektromagnetikoa beharrezkoa denean. Tximistaren babesa
Instalazioa 13

Omada C.ampus Stackable L3 Managed Switch
Bolumen oso altuatagTximistak gertatzen direnean korronteak berehala sor daitezke eta deskarga elektrikoaren bideko airea berehala berotu daiteke 20,000 °C arte. Berehalako korronte hau gailu elektronikoak kaltetzeko nahikoa denez, tximista babesteko neurri eraginkorragoak hartu behar dira. Ziurtatu rack eta gailua lurra ondo loturik daudela. Ziurtatu entxufeak lurrarekin kontaktu ona duela. Mantendu zentzuzko kable-sistema bat eta saihestu eragindako tximistak. Erabili SPD (Surge Protective Device) seinalea kanpoan kableatzen duzunean.
Oharra: Tximistaren aurkako babes neurri zehatzak lortzeko, kontsultatu Tximistaren Babeserako Gida: https://support.omadanetworks.com/r/1004/. Instalazio gunea
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Instalazio-tresnak
Phillips bihurkina ESD-prebentziorako eskumuturreko bilgarri Kableak
Oharra: tresna hauek ez daude gure produktuarekin batera. Behar izanez gero, bereiz eros ditzakezu.
2.4 Produktuen instalazioa
Etengailua aurrealdetik atzealderako beroa xahutzeko funtzioarekin diseinatuta dago. Funtzionatzen duenean, airea behean erakusten den moduan zirkulatzen du. Beroa hobeto xahutzeko, instalatu gailua ondo aireztatutako ingurune batean eta utzi 5 eta 10 cm arteko tarteak gailuaren inguruan.
14 Instalazioa

2-1 irudia

Aire zirkulazioa

Omada C.ampus Stackable L3 Managed Switch

Mahaigaineko instalazioa

Gailua mahaigainean instalatzeko, jarraitu urrats hauek:
1. Ezarri gailua gainazal lau batean, eta hornidura guztiekin gailuaren pisu guztiari eusteko nahikoa sendoa den.

2. Kendu gomazko oinetako paper itsaskorrak.

3. Lotu gomazko oinak gailuaren behealdean, mahaigainean jartzen denean irrist ez dadin.

2-2 irudia

Mahaigaineko instalazioa

Oinak Gailuaren koskaren behealdea

Rack-en instalazioa

Paketeak rack-muntatzeko euskarri ezberdinen 6 pare ditu, haien argazkiak behean azaltzen dira eta benetako produktuetatik desberdinak izan daitezke.

2-3 irudia

Muntatzeko euskarriak

Screw Hole Group 2

Bracket D Bracket C Bracket B Bracket A

Screw Hole Group 1
Screw Hole Group 3

Parentesia F

Screw Hole Group 4-2 (for device with 420mm depth)

Screw Hole Group 5

Torlojuaren zuloa

4-1 taldea

Screw Hole Group 4-3

(for device with 380mm depth)

(for device with

460mm depth)

E parentesia

Instalazioa 15

Omada C.ampus Stackable L3 Managed Switch

Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:

Metodoa

Erakustaldia

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)

Rack Distance
(For device with a depth of 380mm)

Rack Distance
(For device with a depth of 420mm)

Rack Distance
(For device with a depth of 460mm)

498-640mm 538-680mm 578-720mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)

477-498mm 517-538mm 557-578mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)

429-477mm 469-517mm 509-557mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)

410-429mm 450-469mm 490-509mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)

357-410mm 397-450mm 437-490mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)

282-410mm 322-450mm 362-490mm

16 Instalazioa

Omada C.ampus Stackable L3 Managed Switch

Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)

555-936mm 555-936mm 555-936mm

Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)

743-1121mm 743-1121mm 743-1121mm

Gailua instalatzeko, jarraitu behean azaltzen diren argibideak:

1. Attach the M6 nuts to the racks.

2-4 irudia

Securing M6 Nuts

×8

2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.

2-5 irudia

Installing Brackets on Racks

or

3. Attach the brackets A & D/F to the switch with the provided M3 screws.

Instalazioa 17

Omada C.ampus Stackable L3 Managed Switch

2-6 irudia

Installing Brackets on Switch

4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.

2-7 irudia

Installing Switch on Racks

Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.

18 Instalazioa

Omada C.ampus Stackable L3 Managed Switch

Elikatze-moduluaren instalazioa

S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.

2-8 irudia

Appearance of the Power Supply Module

AC korronte kablearen konektorea
FAN

Atxikipen-klipak

Extraction Handle

LED

Locking Strap Slot Release Handle

Elikatze-hornidura modulu bat gehiago gehitu behar baduzu, jarraitu urrats hauek:

1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.

2. Press the extraction handle of the module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.

3. Release the extraction handle to fix the power supply module in place.

2-9 irudia

Energia hornitzeko modulua instalatzea

Askatu heldulekua

Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
Instalazioa 19

Omada C.ampus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap

Elikatze-hornidura modulua kendu behar baduzu, jarraitu urrats hauek:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Haizagailu Moduluaren Instalazioa
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
2-11 Irudia Fan Moduluaren itxura
LED

20 Instalazioa

Extraction Handle Retainer Clips Release Handle

Omada C.ampus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded. 2. Press the extraction handle of the module with one hand, and pull the extraction handle until the
module completely comes out of the chassis.
2-12 Irudia Kaltetutako haizagailuaren modulua kentzea
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Instalazioa 21

Omada C.ampus Stackable L3 Managed Switch

3. kapitulua Konexioa

3.1 Ethernet ataka

Konektatu etengailuaren Ethernet ataka ordenagailura RJ45 kablearen bidez, hurrengo irudian agertzen den moduan.

3-1 irudia

RJ45 ataka konektatzea

RJ45 portua

RJ45 kablea

3.2 10G SFP+/25G SFP28/100G QSFP28 Slot

The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module

3-2 irudia

Inserting the Fiber Module

Slot Fiber Module

3.3 Kontsolaren ataka
CLI (Komando-lerroko interfazea) etengailua kudeatzeko aukera ematen dizu, beraz, CLI kargatu dezakezu ordenagailuak edo terminalak etengailuaren kontsola-portuan kable baten bidez konektatu ondoren (RJ45 kontsola-kable bat ematen da, baina C motako kablerik ez).
Konektatu gailuaren RJ45 kontsolako ataka ordenagailuarekin kontsolaren kablearen bidez, hurrengo irudiak erakusten duen moduan.

22 Konexioa

3-3 irudia

Kontsola (RJ45) ataka konektatzea

Omada C.ampus Stackable L3 Managed Switch

Konektatu gailuaren C motako kontsolaren ataka zure ordenagailuarekin C motako kablearen bidez (emandakoa ez dena) hurrengo irudiak erakusten duen moduan.

3-4 irudia

Kontsola (USB) ataka konektatzea

Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Egiaztatu instalazioa
Instalazioa amaitu ondoren, egiaztatu elementu hauek: Gailuaren inguruan 5 eta 10 cm arteko tartea egon behar da aireztapenerako eta ziurtatu aire-fluxua dela.
egokia da. Liburuatagelikadura-iturriaren e sarrerako bolumenaren eskakizuna betetzen dutaggailuaren e. Korronte entxufea, gailua eta rack ondo lotuta daude. Gailua sareko beste gailu batzuetara behar bezala konektatuta dago.
Konexioa 23

Omada C.ampus Stackable L3 Managed Switch

3.5 Piztu

Entxufatu hornitutako korronte-kablearen konektore emea gailuaren korronte-hartunean eta konektatu konektore positiboa korronte-hartune batean, hurrengo irudiak erakusten duen moduan. Ziurtatu voltagelikadura-iturriaren e sarrerako bolumenaren eskakizuna betetzen dutage (100-240 V~ 50/60 Hz).

3-5 irudia

Elikadura iturrira konektatzen

Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.

3.6 Hasieratzea
Gailua piztu ondoren, pizteko auto-proba hasten da. Gailuak ondo funtzionatzen duela ziurtatzeko proba sorta bat egiten da automatikoki. Bitarte horretan, bere LED adierazleek hurrenkera honetan erantzungo dute:
1. PWR LED adierazlea etengabe pizten da. SYS LED eta portu guztien LED adierazleak itzalita mantentzen dira.
2. Minutu bat igaro ondoren, ataka guztietako SYS LED eta LED adierazleak kliskatu egingo dira une batez eta gero itzali egingo dira.
3. Zenbait segundo geroago, SYS LED adierazleak keinu egingo du, eta horrek hasierako arrakasta izan duela adierazten du.
3.7 Pila-topologia
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:

Aldatu

Eredu bateragarriak

Kantitatea

S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

24 Konexioa

Omada C.ampus Stackable L3 Managed Switch

S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S7500-26XF6Y S7500-26XF6Y

S7500-48XF4C S7500-48XF4C

S7500-24Y4C S7500-24Y4C

S7500-48Y8C S7500-48Y8C

S7500-32C

S7500-32C

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

Eszenatoki desberdinetarako hiru pila-topologia-egitura daude, mesedez eraiki topologia egokia zure beharren arabera:

1. Katearen topologia: katearen topologia nahiko sinplea da eta ez du lehen eta azken unitatearen arteko kable konexiorik behar. Distantzia luzerako pilatzeko egokia da, baina bere fidagarritasuna nahiko baxua da.

3-6 irudia

Katearen Topologia

Pilatzeko ataka 2. taldea
Pilatzeko ataka 1. taldea

2. Eraztun-topologia: Eraztun-topologiak fidagarritasun handiagoa du kate-topologiarekin alderatuta. Eraztun-topologiako kateetako bat deskonektatzen denean, eraztun-topologia kate-topologia bihurtzen da, baina pila-sistema osoak normalean funtziona dezake oraindik. Eraztun-topologiak lehen eta azken unitatearen arteko kable konexioa behar du, beraz, ez da egokia distantzia luzerako pilatzeko.

3-7 irudia

Eraztun Topologia

Pilatzeko ataka 2. taldea

Pilatzeko ataka 1. taldea

Konexioa 25

Omada C.ampus Stackable L3 Managed Switch

3. Izarren topologia: Star topologia etengailuak etengailu nagusi zentral batera konektatzen ditu, beraz, kideen etengailuen arteko datuen birbidaltze-tasa nabarmen handitu dezake kudeaketa bateratua eskaintzen duen bitartean.

3-8 irudia

Izarren Topologia

Pilatzeko ataka 2. taldea

Pilatzeko ataka 3. taldea

Pilatzeko ataka 1. taldea

Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.

26 Konexioa

Omada C.ampus Stackable L3 Managed Switch

4. kapitulua Konfigurazioa

4.1 Konfigurazioa amaituview
Etengailuak bi konfigurazio aukera onartzen ditu:
Modu autonomoa: konfiguratu eta kudeatu etengailua bakarka. Kontrolagailu modua: sareko gailuak zentralki konfiguratu eta kudeatu. Gomendagarria da
eskala handiko sarea, gailu masiboz osatua, hala nola sarbide puntuak, etengailuak eta pasabideak.
Oharra: etengailua modu autonomotik kontrolagailu modura aldatzen denean, etengailuaren konfigurazioak galduko dira. Xehetasunetarako, ikusi erlazionatutako dokumentuak gure ofizialaren deskarga zentroan webgunea: https://support.omadanetworks.com/product/.

4.2 Modu autonomoa

Modu autonomoan, erabili ordenagailu bat etengailua konfiguratzeko eta kudeatzeko GUI (Erabiltzaile-Interfaze Grafikoa) edo CLI (komando-lerroko interfazea) erabiliz.

4-1 irudia

Modu autonomorako topologia

Aldatu

PC

GUI erabiliz
1. Etengailuaren kudeaketa orrira sartzeko, ziurtatu etengailua eta ordenagailua azpisare berean daudela. Ireki arakatzaile bat eta idatzi etengailuaren IP helbidea helbidearen eremuan, eta sakatu Sartu tekla.
Kommutadoreak IP helbidea DHCP zerbitzaritik lortzen badu (normalean atebide bat), bilatu kommutadorearen IP helbidea DHCP zerbitzarian.
Hala ez bada, erabili lehenetsitako 192.168.0.1 IP helbidea switcharen kudeaketa orria abiarazteko.

2. Lehen aldiz saioa hasten duzunean, ezarri erabiltzaile-izena eta pasahitza zure sarea eta gailuak hobeto babesteko. Horren ondoren, sistemak automatikoki birbideratuko zaitu saioa hasteko interfazera, sortutako kredentzial berriekin autentifikatzeko.

3. Saioa hasi ondoren, orri nagusia agertuko da. Goiko eta ezkerreko menuetan klik egin dezakezu dagozkien funtzioak konfiguratzeko.
Konfigurazio zehatzetarako, ikusi Erabiltzailearen Gida eta CLI Gidara. Gidak gure ofizialaren deskarga zentroan aurki daitezke webgunea: https://support.omadanetworks.com/product/.
CLI erabiliz Konfiguratu Telnet edo SSH konexio bat etengailua CLI bidez sartzeko.

Konfigurazioa 27

Omada C.ampus Stackable L3 Managed Switch

Erabili kontsolaren ataka etengailuan sartzeko. Kontsolaren ataka erabiltzean, abiarazi terminalaren emulazio programa (adibidez, Hyper Terminala) ordenagailuan eta konfiguratu terminalaren emulazio programa honela:

Baud-tasa 38400 bps

Datu-bitak 8

Parekidetasuna Bat ere ez

Gelditu bits 1

Emaria Kontrola Bat ere ez

Konfigurazio zehatzetarako, ikusi Erabiltzailearen Gida eta CLI Gidara. Gidak gure ofizialaren deskarga zentroan aurki daitezke webgunea: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.

4.3 Kontrolagailu modua
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Pro Hardware Controller (C5300)

Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).

4-2 irudia

Manage the network via Omada Pro Hardware Controller (C5300)

Gateway Switch

Omada Pro Hardware Controller (C5300) EAP
28 Konfigurazioa

EAP

EAP

Bezeroak

Omada C.ampus Stackable L3 Managed Switch

Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.

1. Bilatu pasabidearen IP helbidea. Ireki komando-lerroa zure ordenagailuan eta idatzi ipconfig. Emaitzen zerrendan, bilatu Pasabide Lehenetsia, hau da, pasabidearen IP helbidea ere.
2. Abiarazi a web arakatzailea eta sartu pasabidearen IP helbidea. Hasi saioa pasabidearen kontuan web orrialdea. Ondoren, joan Sarea > LAN > DHCP Bezeroen Zerrendara zure kontrolagailuaren IP helbidea bere MAC helbidearen arabera aurkitzeko.
3. Sartu zure kontrolagailuaren IP helbidea helbide-barran irekitzeko web orrialdea.
4. On the Omada Pro Controller’s web orrialdea, jarraitu morroiari konfigurazio azkarra osatzeko.
5. Konfigurazio azkarraren ondoren, saioa hasteko orria agertzen da. Sartu sortu dituzun erabiltzaile-izena eta pasahitza eta egin klik Hasi saioa. Ondoren, kontrolagailua gehiago konfigura dezakezu.
6. Gailuak urrunetik kudeatu nahi badituzu, jarraitu hurrengo urratsak:
a. Ziurtatu Cloud Access gaituta dagoela zure kontrolagailuan. Lehenespenez, Hodeiko sarbidea gaituta dago. Ziurtatu Cloud LED-a poliki-poliki keinuka ari dela.

b. Abiarazi a web arakatzailea eta sartu https://omada.tplinkcloud.com helbide-barran. Sartu zure TP-Link ID eta pasahitza saioa hasteko. Sakatu + Gehitu kontrolagailua eta aukeratu Hardware kontrolatzailea zure kontrolagailua gehitzeko. Ondoren, kontrolagailua gehiago konfigura dezakezu.

For more details, refer to the Installation Guide of C5300.

Omada Pro Software Controller bidez

Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.

4-3 irudia

Kudeatu sarea Omada Pro Software Controller bidez

Pasabidea

Aldatu

Kontrolatzailea

Omada Pro Software Controller AP

AP

AP

Host PCan exekutatzen

Bezeroak

Konfigurazioa 29

Omada C.ampus Stackable L3 Managed Switch

1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web orrialdea. Hala ez bada, sakatu Abiarazi arakatzailea sarea kudeatzeko.
2. On the Omada Pro Controller’s web orrialdea, jarraitu morroiari konfigurazio azkarra osatzeko.
3. Konfigurazio azkarraren ondoren, saioa hasteko orria agertzen da. Sartu sortu dituzun erabiltzaile-izena eta pasahitza eta egin klik Hasi saioa. Ondoren, kontrolagailua gehiago konfigura dezakezu.
4. Gailuak urrunetik kudeatu nahi badituzu, jarraitu hurrengo urratsak:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web orrialdean, joan Ezarpenak > Hodeirako sarbidea Hodeirako sarbidea gaitzeko eta zure TP-Link ID lotzeko. Konfigurazio azkarrean konfiguratu baduzu, saltatu urrats hau.
b. Abiarazi a web arakatzailea eta sartu https://omada.tplinkcloud.com helbide-barran. Sartu zure TP-Link IDa eta pasahitza saioa hasteko. Zure TP-Link IDarekin lotu diren kontrolagailuen zerrenda agertuko da. Ondoren, Abiarazi sakatu dezakezu kontrolagailua gehiago konfiguratzeko.

Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.

Omada Pro hodeian oinarritutako kontrolagailuaren bidez

Omada Pro Hodeian oinarritutako kontrolagailua alternatiba ona da software kontrolagailua ordenagailu batean instalatu beharrik gabe.

Gainera, lizentziak erosi behar dira.

4-4 irudia

Kudeatu sarea Omada Pro Hodeian oinarritutako kontrolagailuaren bidez

Omada hodeia

Pasabidea

Aldatu

AP

AP

AP

AP

Bezeroak
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Log in with
your TP-Link ID.
30 Konfigurazioa

Omada C.ampus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
you can launch the controller to adopt and manage devices. * Omada App With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official webgunea: https://support.omadanetworks.com/product/.
Konfigurazioa 31

Omada C.ampus Stackable L3 Managed Switch
A eranskina Arazoak konpontzea
1.G. Zer egin dezaket etengailuaren erabiltzaile izena eta pasahitza ahaztuz gero?
1. Konektatu ordenagailuaren kontsola ataka etengailuaren kontsola atakara eta ireki terminalaren emulazio programa bat.
2. Itzali eta berrabiarazi etengailua. Egin terminalaren emulazio programak adierazitako ekintza bootUtil menura iristeko. Ekintza desberdina da produktu batetik bestera. Ekintza posibleak behean zerrendatzen dira: · Sakatu edozein tekla abiarazte automatikoa gelditzeko. · Sakatu CTRL-B bootUtil menura iristeko.
3. bootUtil menua agertuko da. Sartu 6 zenbakia “Pasahitza berreskuratzea” aukera hautatzeko eta idatzi Y erabiltzaile eta pasahitz guztiak ezabatzeko. Ondoren, erabiltzaile-izena eta pasahitza berrezarri ditzakezu.
2.G. Zergatik funtzionatzen du PWR LEDak modu anormalean? PWR/Power LEDa piztuta egon beharko litzateke energia-sistemak normal funtzionatzen duenean. PWR/Power LEDak modu anormalean funtzionatzen badu, jarraitu urrats hauek:
1. Ziurtatu kablea behar bezala konektatuta dagoela eta kontaktua normala dela. 2. Ziurtatu bolumena...tagelikadura-iturriaren e sarrerako bolumenaren eskakizuna betetzen dutagren e
etengailua.
Q3. Zer egin behar dut atzitu ezin badut web kudeaketa orria? Saiatu honako hau:
1. Egiaztatu etengailuko portuen LED guztiak eta ziurtatu Ethernet kablea behar bezala konektatuta dagoela. 2. Saiatu etengailuko beste ataka bat eta ziurtatu Ethernet kablea egokia dela eta normal funtzionatzen duela. 3. Itzali etengailua eta pixka bat igaro ondoren, piztu berriro. 4. Ziurtatu zure ordenagailuaren IP helbidea etengailuaren azpisarean ezarrita dagoela. 5. Oraindik ezin bazara sartu konfigurazio orrira, berrezarri etengailua fabrikako lehenetsietara. Gero
zure ordenagailuaren IP helbidea 192.168.0.x gisa ezarri behar da ("x" 2tik 254ra bitarteko edozein zenbaki da) eta azpisare-maskara 255.255.255.0 gisa.
4.G. Zergatik ez da terminalaren emulazio programa behar bezala bistaratzen? Saiatu honako hau:
1. Ziurtatu elikadura iturria normala dela eta kontsolaren kablea behar bezala konektatuta dagoela. 2. Egiaztatu kontsolaren kablea mota egokia den. 3. Ziurtatu terminalaren emulazio programaren parametroak zuzenak direla: konfiguratu Bits segundoko
38400 gisa, Datu-bitak 8 gisa, Parekidetasuna Bat ere ez, Gelditzeko bitak 1 gisa eta Fluxuaren kontrola Bat ere ez.
32 A eranskina Arazoak konpontzea

Omada C.ampus Stackable L3 Managed Switch

B eranskina Zehaztapenak

Specifications for S6500 Series Switches

Elementua

Edukia

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x

Arauak

IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)

IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)

S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54

B eranskina Zehaztapenak 33

Omada C.ampus Stackable L3 Managed Switch

PoE aurrekontua

For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)

Operating Temperature & Altitude

For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

Biltegiratze-tenperatura -40 °C eta 70 °C (-40 °F eta 158 °F)

Funtzionamenduaren hezetasuna % 10 eta % 90 RH Kondentsaziorik gabekoa

Biltegiratze Hezetasuna

% 5 eta % 90 RH Kondentsaziorik gabekoa

34 B eranskina Zehaztapenak

Omada C.ampus Stackable L3 Managed Switch

Specifications for S7500 Series Switches

Elementua

Edukia

Arauak

IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)

1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)

LED
Operating Temperature & Altitude

S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters

Biltegiratze-tenperatura -40 °C eta 70 °C (-40 °F eta 158 °F)

Funtzionamenduaren hezetasuna % 10 eta % 90 RH Kondentsaziorik gabekoa

Biltegiratze Hezetasuna

% 5 eta % 90 RH Kondentsaziorik gabekoa

For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Onartutako altitudea itsas mailatik 5000 m-ra bitartekoa da. Kontuan izan behar da altitudea 2000 m-tik gorakoa denean, 220 metroko igoera bakoitzeko, funtzionamendu-tenperatura maximoa 1 °C (1.8 °F) jaitsiko dela.

B eranskina Zehaztapenak 35

Omada C.ampus Stackable L3 Managed Switch

Elikatze-hornidura-moduluen zehaztapenak

PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)

Potentzia Sarrera

100 V­240 V~ 50/60 Hz 8A

100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)

100 V­240 V~ 50/60 Hz 7A

Irteera boltage

Primary: 53.5 VDC Standby: 12 VDC

Primary: 53.5 VDC Standby: 12 VDC

Primary: 12 VDC Standby: 12 VDC

Irteera Korrontea

9.35 A (Gehienez)

16.5 A (Gehienez)

45 A (Gehienez)

Irteera Potentzia

500 W (gehienez)

900 W (gehienez)

550 W (gehienez)

Altuera operatiboa

For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m

36 B eranskina Zehaztapenak

CE markako abisua
Hau A klaseko produktua da. Etxeko ingurunean, produktu honek irrati-interferentziak sor ditzake, eta, kasu horretan, erabiltzaileak neurri egokiak hartu behar ditu.
EBko Adostasun Adierazpena
TP-Linkek hemen adierazten du etengailuak 2014/30/EB, 2014/35/EB, 2011/65/EB eta (EB)2015/863 zuzentarauen oinarrizko eskakizunak eta beste xedapen garrantzitsuak betetzen dituela. Jatorrizko EBko Adostasun Adierazpena https://www.tp-link.com/en/support/ce/ helbidean aurki daiteke.
Erresuma Batuko Adostasun Adierazpena
TP-Linkek hemen adierazten du etengailuak 2016ko Bateragarritasun Elektromagnetikoko Araudiaren eta 2016ko Ekipamendu Elektrikoen (Segurtasuna) Araudiaren oinarrizko eskakizunak eta beste xedapen garrantzitsuak betetzen dituela. Erresuma Batuko Adostasun Adierazpen originala https://www.tp-link.com/support/ukca/ helbidean aurki daiteke.
, .
KONTUZ:
Polo bikoitza, fusio neutroa. Deskonektatu sare elektrikoa zerbitzuaren aurretik.
Segurtasun Informazioa
· Mantendu gailua uretatik, sutik, hezetasunetik edo ingurune beroetatik urrun. · Ez saiatu gailua desmuntatzen, konpontzen edo aldatzen. Zerbitzua behar baduzu, jarri gurekin harremanetan. · Jarri gailua beheko gainazala beherantz. · Elikadura-kablearen entxufea deskonektatzeko gailu gisa erabiltzen da, entxufea izango da
erraz eskura daiteke. · Konektatu produktua lurrerako konexioa duten hormako entxufeetara, elikatze-kablearen bidez.
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
bateriak.

· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.

Mesedez, irakurri eta jarraitu goiko segurtasun-informazioa gailua funtzionatzerakoan. Ezin dugu bermatu gailua gaizki erabiltzeagatik istripurik edo kalterik gertatuko ez denik. Mesedez, erabili produktu hau kontu handiz eta erabili zure ardurapean.

Laguntza teknikoa, erabiltzaileentzako gidak eta bestelako informazioa lortzeko, bisitatu https://support.omadanetworks.com/ edo eskaneatu QR kodea.
© 2026 TP-Link 7100002759 REV2.0.1

Dokumentuak / Baliabideak

PDF thumbnailL3 Campus Stackable Managed Switch
User Manual · L3 Campus Stackable Managed Switch, L3, Campus Stackable Managed Switch, Stackable Managed Switch, Managed Switch, Switch

Erreferentziak

Galdera bat egin

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Galdera bat egin

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.